Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- HAGER
Technical specifications
Rated permanent current Iu
800A
Power loss
153.60W
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Suitable for DIN rail (top hat rail) mounting
No
Complete device with protection unit
Yes
Type of control element
Toggle
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP40
Integrated earth fault protection
No
Overload release current setting
320 - 800A
Position of connection for main current circuit
Front side
Rated voltage
220 - 690V
Device construction
Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional
No
Number of poles
4
Adjustment range undelayed short-circuit release
4480 - 9600A
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Screw connection
With switched-off indicator
No
Number of auxiliary contacts as normally closed contact
0
With integrated under voltage release
No
Adjustment range short-term delayed short-circuit release
0 - 0A
Number of auxiliary contacts as change-over contact
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
HEE801H
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- HAGER
Technical specifications
Rated permanent current Iu
800A
Power loss
153.60W
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Suitable for DIN rail (top hat rail) mounting
Complete device with protection unit
Type of control element
Toggle
Motor drive integrated
Motor drive optional
Degree of protection (IP)
IP40
Integrated earth fault protection
Overload release current setting
320 .. 800A
Position of connection for main current circuit
Front side
Rated voltage
220 .. 690V
Device construction
Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional
Number of poles
4
Adjustment range undelayed short-circuit release
4480 .. 9600A
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Screw connection
With switched-off indicator
Number of auxiliary contacts as normally closed contact
0
With integrated under voltage release
Adjustment range short-term delayed short-circuit release
0 .. 0A
Number of auxiliary contacts as change-over contact
0