Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- HAGER
Technical specifications
Version as main switch
Yes
Version as maintenance-/service switch
Yes
Version as reversing switch
No
Number of switches
1
Version as emergency stop installation
No
Version as safety switch
Yes
Rated permanent current Iu
32A
Rated short-time withstand current lcw
1.26kA
Number of auxiliary contacts as normally closed contact
0
Rated operation power at AC-23, 400 V
14kW
Conditioned rated short-circuit current Iq
50kA
Number of poles
4
Motor drive integrated
No
Device construction
Built-in device fixed built-in technique
Suitable for floor mounting
Yes
Max. rated operation voltage Ue AC
415V
Motor drive optional
No
Switching power at 400 V
21kW
Suitable for front mounting centre
No
Number of auxiliary contacts as change-over contact
0
Type of control element
Short thumb-grip
Voltage release optional
No
Rated permanent current at AC-21, 400 V
32A
With pre-assembled cabling
No
Rated permanent current at AC-23, 400 V
32A
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP), front side
IP20
Width
60mm
Rated operating voltage
380 - 415V
Depth
69mm
Height
68mm
Interlockable
Yes
Suitable for front mounting 4-hole
No
Suitable for distribution board installation
Yes
Suitable for intermediate mounting
No
Width in number of modular spacings
3.5
Colour control element
Grey
Number of auxiliary contacts as normally open contact
0
Degree of protection (NEMA)
Other
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
HAB403
Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- HAGER
Technical specifications
Version as main switch
Version as maintenance-/service switch
Version as reversing switch
Number of switches
1
Version as emergency stop installation
Version as safety switch
Rated permanent current Iu
32A
Rated short-time withstand current lcw
1.26kA
Number of auxiliary contacts as normally closed contact
0
Rated operation power at AC-23, 400 V
14kW
Conditioned rated short-circuit current Iq
50kA
Number of poles
4
Motor drive integrated
Device construction
Built-in device fixed built-in technique
Suitable for floor mounting
Max. rated operation voltage Ue AC
415V
Motor drive optional
Switching power at 400 V
21kW
Suitable for front mounting centre
Number of auxiliary contacts as change-over contact
0
Type of control element
Short thumb-grip
Voltage release optional
Rated permanent current at AC-21, 400 V
32A
With pre-assembled cabling
Rated permanent current at AC-23, 400 V
32A
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP), front side
IP20
Width
60mm
Rated operating voltage
380 .. 415V
Depth
69mm
Height
68mm
Interlockable
Suitable for front mounting 4-hole
Suitable for distribution board installation
Suitable for intermediate mounting
Width in number of modular spacings
3.5
Colour control element
Grey
Number of auxiliary contacts as normally open contact
0
Degree of protection (NEMA)
Other