Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- HAGER
Technical specifications
Version as maintenance-/service switch
Yes
Version as main switch
Yes
Number of switches
1
Version as reversing switch
No
Version as emergency stop installation
No
Max. rated operation voltage Ue AC
415V
Version as safety switch
Yes
Rated permanent current Iu
20A
Rated operating voltage
380 - 415V
Rated operation power at AC-23, 400 V
9kW
Switching power at 400 V
13kW
Rated short-time withstand current lcw
1.26kA
Rated permanent current at AC-23, 400 V
20A
Rated permanent current at AC-21, 400 V
20A
Conditioned rated short-circuit current Iq
50kA
Number of poles
4
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
Voltage release optional
No
Motor drive optional
No
Device construction
Built-in device fixed built-in technique
Suitable for front mounting 4-hole
No
Motor drive integrated
No
Suitable for front mounting centre
No
Suitable for floor mounting
Yes
Colour control element
Grey
Type of control element
Short thumb-grip
Type of electrical connection of main circuit
Screw connection
Suitable for distribution board installation
Yes
Suitable for intermediate mounting
No
Number of auxiliary contacts as normally open contact
0
With pre-assembled cabling
No
Interlockable
Yes
Width
60mm
Degree of protection (IP), front side
IP20
Height
68mm
Degree of protection (NEMA)
Other
Depth
69mm
Width in number of modular spacings
3.5
From same serie
HAB402

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- HAGER
Technical specifications
Version as maintenance-/service switch
Version as main switch
Number of switches
1
Version as reversing switch
Version as emergency stop installation
Max. rated operation voltage Ue AC
415V
Version as safety switch
Rated permanent current Iu
20A
Rated operating voltage
380 .. 415V
Rated operation power at AC-23, 400 V
9kW
Switching power at 400 V
13kW
Rated short-time withstand current lcw
1.26kA
Rated permanent current at AC-23, 400 V
20A
Rated permanent current at AC-21, 400 V
20A
Conditioned rated short-circuit current Iq
50kA
Number of poles
4
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
Voltage release optional
Motor drive optional
Device construction
Built-in device fixed built-in technique
Suitable for front mounting 4-hole
Motor drive integrated
Suitable for front mounting centre
Suitable for floor mounting
Colour control element
Grey
Type of control element
Short thumb-grip
Type of electrical connection of main circuit
Screw connection
Suitable for distribution board installation
Suitable for intermediate mounting
Number of auxiliary contacts as normally open contact
0
With pre-assembled cabling
Interlockable
Width
60mm
Degree of protection (IP), front side
IP20
Height
68mm
Degree of protection (NEMA)
Other
Depth
69mm
Width in number of modular spacings
3.5