Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Detection capability for test bodies
-mm
Resolution of the light curtain
-mm
Number of semiconductor outputs with signalling function
0
Type of switching output of the OSSD
PNP/PNP
Number of contact energized outputs with signalling function
0
Number of protected contact energized outputs
0
Width sensor
29.4mm
Type of electric connection
Connector M12
Length of sensor
31mm
Number of protected semiconductor outputs
2
Operation agent-safety class
Safety class 3
Fade-out possible
No
Type of interface for safety communication
Other
Height of sensor
1077mm
With muting function
Yes
Explosion safety category for gas
None
Scope of delivery of the one-way system
Transmitter and receiver
Ambient temperature
-10 - 55°C
Max. output current at protected output
400mA
Explosion safety category for dust
None
Cascadable
Yes
Type of safety according to IEC 61496-1
4
Safety field height
910mm
Switching voltage of OSSD at state "high"
24V
Rated control supply voltage Us at DC
24 - 24V
Override possible
No
Transmission range of the safety field
12m
Reduced resolution
Yes
Voltage type
AC/DC
With restart blockage
Yes
With beam coding
No
Wavelength of the sensor
950nm
Clock control possible
No
Suitable for safety functions
Yes
Degree of protection (IP)
IP65
Response time
3ms
With monitoring function downstream switching devices
No
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL4E4BB091NS2
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Detection capability for test bodies
-mm
Resolution of the light curtain
-mm
Number of semiconductor outputs with signalling function
0
Type of switching output of the OSSD
PNP/PNP
Number of contact energized outputs with signalling function
0
Number of protected contact energized outputs
0
Width sensor
29.4mm
Type of electric connection
Connector M12
Length of sensor
31mm
Number of protected semiconductor outputs
2
Operation agent-safety class
Safety class 3
Fade-out possible
Type of interface for safety communication
Other
Height of sensor
1077mm
With muting function
Explosion safety category for gas
None
Scope of delivery of the one-way system
Transmitter and receiver
Ambient temperature
-10 .. 55°C
Max. output current at protected output
400mA
Explosion safety category for dust
None
Cascadable
Type of safety according to IEC 61496-1
4
Safety field height
910mm
Switching voltage of OSSD at state "high"
24V
Rated control supply voltage Us at DC
24 .. 24V
Override possible
Transmission range of the safety field
12m
Reduced resolution
Voltage type
AC/DC
With restart blockage
With beam coding
Wavelength of the sensor
950nm
Clock control possible
Suitable for safety functions
Degree of protection (IP)
IP65
Response time
3ms
With monitoring function downstream switching devices