XUSL4E30H181L
Code: 1759566
Code: 1759566
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Number of semiconductor outputs with signalling function
0
Number of protected semiconductor outputs
2
Type of interface for safety communication
Other
Fade-out possible
No
Height of sensor
1863mm
Width sensor
29.4mm
Length of sensor
31mm
Operation agent-safety class
Safety class 3
Max. output current at protected output
400mA
Explosion safety category for dust
None
Type of switching output of the OSSD
PNP/PNP
Cascadable
No
Ambient temperature
-10 - 55°C
Resolution of the light curtain
30mm
Override possible
No
Transmission range of the safety field
20m
Voltage type
AC/DC
Reduced resolution
No
With beam coding
No
Number of contact energized outputs with signalling function
0
Scope of delivery of the one-way system
Transmitter and receiver
Type of safety according to IEC 61496-1
4
Type of electric connection
Connector M12
Number of protected contact energized outputs
0
Detection capability for test bodies
30mm
Explosion safety category for gas
None
With muting function
Yes
Response time
13ms
Rated control supply voltage Us at DC
24 - 24V
Switching voltage of OSSD at state "high"
24V
Safety field height
1810mm
Clock control possible
No
With monitoring function downstream switching devices
No
Wavelength of the sensor
950nm
With restart blockage
Yes
Degree of protection (IP)
IP65
Suitable for safety functions
Yes
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL4E30H181L
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Number of semiconductor outputs with signalling function
0
Number of protected semiconductor outputs
2
Type of interface for safety communication
Other
Fade-out possible
Height of sensor
1863mm
Width sensor
29.4mm
Length of sensor
31mm
Operation agent-safety class
Safety class 3
Max. output current at protected output
400mA
Explosion safety category for dust
None
Type of switching output of the OSSD
PNP/PNP
Cascadable
Ambient temperature
-10 .. 55°C
Resolution of the light curtain
30mm
Override possible
Transmission range of the safety field
20m
Voltage type
AC/DC
Reduced resolution
With beam coding
Number of contact energized outputs with signalling function
0
Scope of delivery of the one-way system
Transmitter and receiver
Type of safety according to IEC 61496-1
4
Type of electric connection
Connector M12
Number of protected contact energized outputs
0
Detection capability for test bodies
30mm
Explosion safety category for gas
None
With muting function
Response time
13ms
Rated control supply voltage Us at DC
24 .. 24V
Switching voltage of OSSD at state "high"
24V
Safety field height
1810mm
Clock control possible
With monitoring function downstream switching devices
Wavelength of the sensor
950nm
With restart blockage
Degree of protection (IP)
IP65
Suitable for safety functions
We use cookies to enhance your experience.