XUSL4E30H136N
Code: 1759561
Code: 1759561
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Number of semiconductor outputs with signalling function
0
Number of protected semiconductor outputs
2
Type of interface for safety communication
Other
Fade-out possible
No
Number of contact energized outputs with signalling function
0
Type of switching output of the OSSD
PNP/PNP
Number of protected contact energized outputs
0
Type of electric connection
Connector M12
Length of sensor
31mm
Width sensor
29.4mm
Operation agent-safety class
Safety class 3
Height of sensor
1413mm
Explosion safety category for gas
None
Detection capability for test bodies
30mm
Cascadable
No
Explosion safety category for dust
None
Rated control supply voltage Us at DC
24 - 24V
With monitoring function downstream switching devices
No
With muting function
Yes
With restart blockage
Yes
Ambient temperature
-10 - 55°C
Override possible
No
Resolution of the light curtain
30mm
Response time
17ms
Suitable for safety functions
Yes
Switching voltage of OSSD at state "high"
24V
Reduced resolution
No
Transmission range of the safety field
12m
With beam coding
No
Type of safety according to IEC 61496-1
4
Voltage type
AC/DC
Scope of delivery of the one-way system
Transmitter and receiver
Degree of protection (IP)
IP65
Clock control possible
No
Max. output current at protected output
400mA
Wavelength of the sensor
950nm
Safety field height
1360mm
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL4E30H136N
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Number of semiconductor outputs with signalling function
0
Number of protected semiconductor outputs
2
Type of interface for safety communication
Other
Fade-out possible
Number of contact energized outputs with signalling function
0
Type of switching output of the OSSD
PNP/PNP
Number of protected contact energized outputs
0
Type of electric connection
Connector M12
Length of sensor
31mm
Width sensor
29.4mm
Operation agent-safety class
Safety class 3
Height of sensor
1413mm
Explosion safety category for gas
None
Detection capability for test bodies
30mm
Cascadable
Explosion safety category for dust
None
Rated control supply voltage Us at DC
24 .. 24V
With monitoring function downstream switching devices
With muting function
With restart blockage
Ambient temperature
-10 .. 55°C
Override possible
Resolution of the light curtain
30mm
Response time
17ms
Suitable for safety functions
Switching voltage of OSSD at state "high"
24V
Reduced resolution
Transmission range of the safety field
12m
With beam coding
Type of safety according to IEC 61496-1
4
Voltage type
AC/DC
Scope of delivery of the one-way system
Transmitter and receiver
Degree of protection (IP)
IP65
Clock control possible
Max. output current at protected output
400mA
Wavelength of the sensor
950nm
Safety field height
1360mm
We use cookies to enhance your experience.