XUSL4E30H106NS1
Code: 1759556
Code: 1759556
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Response time
-ms
Type of interface for safety communication
Other
Operation agent-safety class
Safety class 3
Number of contact energized outputs with signalling function
0
Number of protected contact energized outputs
0
Fade-out possible
No
Type of electric connection
Connector M12
Number of semiconductor outputs with signalling function
0
Reduced resolution
No
With monitoring function downstream switching devices
No
With restart blockage
Yes
With beam coding
No
Clock control possible
No
Suitable for safety functions
Yes
Detection capability for test bodies
30mm
Explosion safety category for dust
None
With muting function
Yes
Max. output current at protected output
400mA
Override possible
No
Length of sensor
31mm
Scope of delivery of the one-way system
Transmitter and receiver
Ambient temperature
-10 - 55°C
Number of protected semiconductor outputs
2
Switching voltage of OSSD at state "high"
24V
Type of safety according to IEC 61496-1
4
Safety field height
1060mm
Type of switching output of the OSSD
PNP/PNP
Transmission range of the safety field
12m
Height of sensor
1113mm
Resolution of the light curtain
30mm
Wavelength of the sensor
950nm
Width sensor
29.4mm
Rated control supply voltage Us at DC
24 - 24V
Voltage type
AC/DC
Explosion safety category for gas
None
Cascadable
Yes
Degree of protection (IP)
IP65
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL4E30H106NS1
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Response time
-ms
Type of interface for safety communication
Other
Operation agent-safety class
Safety class 3
Number of contact energized outputs with signalling function
0
Number of protected contact energized outputs
0
Fade-out possible
Type of electric connection
Connector M12
Number of semiconductor outputs with signalling function
0
Reduced resolution
With monitoring function downstream switching devices
With restart blockage
With beam coding
Clock control possible
Suitable for safety functions
Detection capability for test bodies
30mm
Explosion safety category for dust
None
With muting function
Max. output current at protected output
400mA
Override possible
Length of sensor
31mm
Scope of delivery of the one-way system
Transmitter and receiver
Ambient temperature
-10 .. 55°C
Number of protected semiconductor outputs
2
Switching voltage of OSSD at state "high"
24V
Type of safety according to IEC 61496-1
4
Safety field height
1060mm
Type of switching output of the OSSD
PNP/PNP
Transmission range of the safety field
12m
Height of sensor
1113mm
Resolution of the light curtain
30mm
Wavelength of the sensor
950nm
Width sensor
29.4mm
Rated control supply voltage Us at DC
24 .. 24V
Voltage type
AC/DC
Explosion safety category for gas
None
Cascadable
Degree of protection (IP)
IP65
We use cookies to enhance your experience.