XUSL4E30H091LWH
Code: 1759546
Code: 1759546
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Number of protected contact energized outputs
0
Number of semiconductor outputs with signalling function
0
Type of switching output of the OSSD
PNP/PNP
Number of protected semiconductor outputs
2
Type of interface for safety communication
Other
Height of sensor
1070mm
Operation agent-safety class
Safety class 3
Explosion safety category for dust
None
Explosion safety category for gas
None
Max. output current at protected output
400mA
Resolution of the light curtain
30mm
Cascadable
No
Response time
12.5ms
With muting function
Yes
Length of sensor
76mm
Detection capability for test bodies
30mm
Voltage type
AC/DC
Rated control supply voltage Us at DC
24 - 24V
Type of safety according to IEC 61496-1
4
Switching voltage of OSSD at state "high"
24V
Number of contact energized outputs with signalling function
0
Fade-out possible
No
Type of electric connection
Connector M12
Width sensor
75mm
Transmission range of the safety field
17m
Reduced resolution
No
Clock control possible
No
Override possible
No
With beam coding
No
Scope of delivery of the one-way system
Transmitter and receiver
Safety field height
910mm
Ambient temperature
-25 - 55°C
With monitoring function downstream switching devices
No
Degree of protection (IP)
IP65
Suitable for safety functions
Yes
Wavelength of the sensor
950nm
With restart blockage
Yes
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL4E30H091LWH
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Number of protected contact energized outputs
0
Number of semiconductor outputs with signalling function
0
Type of switching output of the OSSD
PNP/PNP
Number of protected semiconductor outputs
2
Type of interface for safety communication
Other
Height of sensor
1070mm
Operation agent-safety class
Safety class 3
Explosion safety category for dust
None
Explosion safety category for gas
None
Max. output current at protected output
400mA
Resolution of the light curtain
30mm
Cascadable
Response time
12.5ms
With muting function
Length of sensor
76mm
Detection capability for test bodies
30mm
Voltage type
AC/DC
Rated control supply voltage Us at DC
24 .. 24V
Type of safety according to IEC 61496-1
4
Switching voltage of OSSD at state "high"
24V
Number of contact energized outputs with signalling function
0
Fade-out possible
Type of electric connection
Connector M12
Width sensor
75mm
Transmission range of the safety field
17m
Reduced resolution
Clock control possible
Override possible
With beam coding
Scope of delivery of the one-way system
Transmitter and receiver
Safety field height
910mm
Ambient temperature
-25 .. 55°C
With monitoring function downstream switching devices
Degree of protection (IP)
IP65
Suitable for safety functions
Wavelength of the sensor
950nm
With restart blockage