XUSL4E30H061LWH
Code: 1759533
Code: 1759533
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Number of contact energized outputs with signalling function
0
Number of semiconductor outputs with signalling function
0
Type of interface for safety communication
Other
Operation agent-safety class
Safety class 3
Width sensor
75mm
Type of electric connection
Connector M12
Length of sensor
76mm
Explosion safety category for dust
None
Number of protected semiconductor outputs
2
Fade-out possible
No
Height of sensor
770mm
Type of switching output of the OSSD
PNP/PNP
Type of safety according to IEC 61496-1
4
Override possible
No
Ambient temperature
-25 - 55°C
Explosion safety category for gas
None
Safety field height
610mm
Rated control supply voltage Us at DC
24 - 24V
Scope of delivery of the one-way system
Transmitter and receiver
Response time
9ms
Reduced resolution
No
Transmission range of the safety field
17m
Switching voltage of OSSD at state "high"
24V
Voltage type
AC/DC
Resolution of the light curtain
30mm
Max. output current at protected output
400mA
Cascadable
No
With muting function
Yes
Number of protected contact energized outputs
0
With monitoring function downstream switching devices
No
With restart blockage
Yes
Degree of protection (IP)
IP65
Suitable for safety functions
Yes
Clock control possible
No
With beam coding
No
Wavelength of the sensor
950nm
Detection capability for test bodies
30mm
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL4E30H061LWH
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Number of contact energized outputs with signalling function
0
Number of semiconductor outputs with signalling function
0
Type of interface for safety communication
Other
Operation agent-safety class
Safety class 3
Width sensor
75mm
Type of electric connection
Connector M12
Length of sensor
76mm
Explosion safety category for dust
None
Number of protected semiconductor outputs
2
Fade-out possible
Height of sensor
770mm
Type of switching output of the OSSD
PNP/PNP
Type of safety according to IEC 61496-1
4
Override possible
Ambient temperature
-25 .. 55°C
Explosion safety category for gas
None
Safety field height
610mm
Rated control supply voltage Us at DC
24 .. 24V
Scope of delivery of the one-way system
Transmitter and receiver
Response time
9ms
Reduced resolution
Transmission range of the safety field
17m
Switching voltage of OSSD at state "high"
24V
Voltage type
AC/DC
Resolution of the light curtain
30mm
Max. output current at protected output
400mA
Cascadable
With muting function
Number of protected contact energized outputs
0
With monitoring function downstream switching devices
With restart blockage
Degree of protection (IP)
IP65
Suitable for safety functions
Clock control possible
With beam coding
Wavelength of the sensor
950nm
Detection capability for test bodies
30mm