XUSL4E30H046LWH
Code: 1759526
Code: 1759526
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Type of interface for safety communication
Other
Operation agent-safety class
Safety class 3
Height of sensor
620mm
Detection capability for test bodies
30mm
Number of contact energized outputs with signalling function
0
Length of sensor
76mm
Type of electric connection
Connector M12
Type of switching output of the OSSD
PNP/PNP
Number of protected semiconductor outputs
2
Number of semiconductor outputs with signalling function
0
Width sensor
75mm
Fade-out possible
No
Number of protected contact energized outputs
0
Explosion safety category for dust
None
With muting function
Yes
Scope of delivery of the one-way system
Transmitter and receiver
Response time
7.5ms
Explosion safety category for gas
None
Switching voltage of OSSD at state "high"
24V
Type of safety according to IEC 61496-1
4
Resolution of the light curtain
30mm
Rated control supply voltage Us at DC
24 - 24V
Ambient temperature
-25 - 55°C
Voltage type
AC/DC
Reduced resolution
No
Override possible
No
With beam coding
No
Cascadable
No
Max. output current at protected output
400mA
Transmission range of the safety field
17m
Wavelength of the sensor
950nm
Clock control possible
No
Suitable for safety functions
Yes
With monitoring function downstream switching devices
No
Safety field height
460mm
Degree of protection (IP)
IP65
With restart blockage
Yes
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL4E30H046LWH
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Type of interface for safety communication
Other
Operation agent-safety class
Safety class 3
Height of sensor
620mm
Detection capability for test bodies
30mm
Number of contact energized outputs with signalling function
0
Length of sensor
76mm
Type of electric connection
Connector M12
Type of switching output of the OSSD
PNP/PNP
Number of protected semiconductor outputs
2
Number of semiconductor outputs with signalling function
0
Width sensor
75mm
Fade-out possible
Number of protected contact energized outputs
0
Explosion safety category for dust
None
With muting function
Scope of delivery of the one-way system
Transmitter and receiver
Response time
7.5ms
Explosion safety category for gas
None
Switching voltage of OSSD at state "high"
24V
Type of safety according to IEC 61496-1
4
Resolution of the light curtain
30mm
Rated control supply voltage Us at DC
24 .. 24V
Ambient temperature
-25 .. 55°C
Voltage type
AC/DC
Reduced resolution
Override possible
With beam coding
Cascadable
Max. output current at protected output
400mA
Transmission range of the safety field
17m
Wavelength of the sensor
950nm
Clock control possible
Suitable for safety functions
With monitoring function downstream switching devices
Safety field height
460mm
Degree of protection (IP)
IP65
With restart blockage