XUSL4E30H046LWC
Code: 1759525
Code: 1759525
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Type of switching output of the OSSD
PNP/PNP
Fade-out possible
No
Number of contact energized outputs with signalling function
0
Explosion safety category for gas
None
Explosion safety category for dust
None
Scope of delivery of the one-way system
Transmitter and receiver
Number of semiconductor outputs with signalling function
0
Type of electric connection
Connector M12
Number of protected contact energized outputs
0
Height of sensor
620mm
Cascadable
No
Number of protected semiconductor outputs
2
Operation agent-safety class
Safety class 3
Length of sensor
76mm
Reduced resolution
No
Width sensor
75mm
Detection capability for test bodies
30mm
With muting function
Yes
Max. output current at protected output
400mA
Type of interface for safety communication
Other
Ambient temperature
-10 - 55°C
Switching voltage of OSSD at state "high"
24V
Transmission range of the safety field
17m
Resolution of the light curtain
30mm
With beam coding
No
Override possible
No
Wavelength of the sensor
950nm
Type of safety according to IEC 61496-1
4
Safety field height
460mm
Degree of protection (IP)
IP65
Suitable for safety functions
Yes
Voltage type
AC/DC
Rated control supply voltage Us at DC
24 - 24V
With monitoring function downstream switching devices
No
With restart blockage
Yes
Response time
7.5ms
Clock control possible
No
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL4E30H046LWC
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Type of switching output of the OSSD
PNP/PNP
Fade-out possible
Number of contact energized outputs with signalling function
0
Explosion safety category for gas
None
Explosion safety category for dust
None
Scope of delivery of the one-way system
Transmitter and receiver
Number of semiconductor outputs with signalling function
0
Type of electric connection
Connector M12
Number of protected contact energized outputs
0
Height of sensor
620mm
Cascadable
Number of protected semiconductor outputs
2
Operation agent-safety class
Safety class 3
Length of sensor
76mm
Reduced resolution
Width sensor
75mm
Detection capability for test bodies
30mm
With muting function
Max. output current at protected output
400mA
Type of interface for safety communication
Other
Ambient temperature
-10 .. 55°C
Switching voltage of OSSD at state "high"
24V
Transmission range of the safety field
17m
Resolution of the light curtain
30mm
With beam coding
Override possible
Wavelength of the sensor
950nm
Type of safety according to IEC 61496-1
4
Safety field height
460mm
Degree of protection (IP)
IP65
Suitable for safety functions
Voltage type
AC/DC
Rated control supply voltage Us at DC
24 .. 24V
With monitoring function downstream switching devices
With restart blockage
Response time
7.5ms
Clock control possible