XUSL4E30H031N
Code: 1759523
Code: 1759523
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Type of interface for safety communication
Other
Width sensor
29.4mm
Operation agent-safety class
Safety class 3
Scope of delivery of the one-way system
Transmitter and receiver
Number of protected semiconductor outputs
2
Type of switching output of the OSSD
PNP/PNP
Height of sensor
363mm
Fade-out possible
No
Number of semiconductor outputs with signalling function
0
Length of sensor
31mm
Explosion safety category for gas
None
Number of protected contact energized outputs
0
Type of electric connection
Connector M12
Detection capability for test bodies
30mm
Cascadable
No
Resolution of the light curtain
30mm
Max. output current at protected output
400mA
With muting function
Yes
Reduced resolution
No
Transmission range of the safety field
12m
Rated control supply voltage Us at DC
24 - 24V
Clock control possible
No
Safety field height
310mm
Type of safety according to IEC 61496-1
4
Ambient temperature
-10 - 55°C
Response time
5.5ms
Number of contact energized outputs with signalling function
0
Override possible
No
With beam coding
No
Explosion safety category for dust
None
With monitoring function downstream switching devices
No
Degree of protection (IP)
IP65
With restart blockage
Yes
Wavelength of the sensor
950nm
Voltage type
AC/DC
Switching voltage of OSSD at state "high"
24V
Suitable for safety functions
Yes
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL4E30H031N
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Type of interface for safety communication
Other
Width sensor
29.4mm
Operation agent-safety class
Safety class 3
Scope of delivery of the one-way system
Transmitter and receiver
Number of protected semiconductor outputs
2
Type of switching output of the OSSD
PNP/PNP
Height of sensor
363mm
Fade-out possible
Number of semiconductor outputs with signalling function
0
Length of sensor
31mm
Explosion safety category for gas
None
Number of protected contact energized outputs
0
Type of electric connection
Connector M12
Detection capability for test bodies
30mm
Cascadable
Resolution of the light curtain
30mm
Max. output current at protected output
400mA
With muting function
Reduced resolution
Transmission range of the safety field
12m
Rated control supply voltage Us at DC
24 .. 24V
Clock control possible
Safety field height
310mm
Type of safety according to IEC 61496-1
4
Ambient temperature
-10 .. 55°C
Response time
5.5ms
Number of contact energized outputs with signalling function
0
Override possible
With beam coding
Explosion safety category for dust
None
With monitoring function downstream switching devices
Degree of protection (IP)
IP65
With restart blockage
Wavelength of the sensor
950nm
Voltage type
AC/DC
Switching voltage of OSSD at state "high"
24V
Suitable for safety functions