XUSL4E30H026N
Code: 1759521
Code: 1759521
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Number of semiconductor outputs with signalling function
0
Operation agent-safety class
Safety class 3
Number of protected contact energized outputs
0
Width sensor
29.4mm
Number of contact energized outputs with signalling function
0
Length of sensor
31mm
Detection capability for test bodies
30mm
Explosion safety category for dust
None
Type of electric connection
Connector M12
Scope of delivery of the one-way system
Transmitter and receiver
Max. output current at protected output
400mA
Override possible
No
Ambient temperature
-10 - 55°C
Explosion safety category for gas
None
Reduced resolution
No
Response time
5ms
Resolution of the light curtain
30mm
Safety field height
260mm
With restart blockage
Yes
Switching voltage of OSSD at state "high"
24V
Height of sensor
313mm
Number of protected semiconductor outputs
2
Type of interface for safety communication
Other
Type of switching output of the OSSD
PNP/PNP
Voltage type
AC/DC
With beam coding
No
With monitoring function downstream switching devices
No
Rated control supply voltage Us at DC
24 - 24V
Wavelength of the sensor
950nm
Clock control possible
No
Cascadable
No
With muting function
Yes
Type of safety according to IEC 61496-1
4
Fade-out possible
No
Suitable for safety functions
Yes
Degree of protection (IP)
IP65
Transmission range of the safety field
17m
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL4E30H026N
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Number of semiconductor outputs with signalling function
0
Operation agent-safety class
Safety class 3
Number of protected contact energized outputs
0
Width sensor
29.4mm
Number of contact energized outputs with signalling function
0
Length of sensor
31mm
Detection capability for test bodies
30mm
Explosion safety category for dust
None
Type of electric connection
Connector M12
Scope of delivery of the one-way system
Transmitter and receiver
Max. output current at protected output
400mA
Override possible
Ambient temperature
-10 .. 55°C
Explosion safety category for gas
None
Reduced resolution
Response time
5ms
Resolution of the light curtain
30mm
Safety field height
260mm
With restart blockage
Switching voltage of OSSD at state "high"
24V
Height of sensor
313mm
Number of protected semiconductor outputs
2
Type of interface for safety communication
Other
Type of switching output of the OSSD
PNP/PNP
Voltage type
AC/DC
With beam coding
With monitoring function downstream switching devices
Rated control supply voltage Us at DC
24 .. 24V
Wavelength of the sensor
950nm
Clock control possible
Cascadable
With muting function
Type of safety according to IEC 61496-1
4
Fade-out possible
Suitable for safety functions
Degree of protection (IP)
IP65
Transmission range of the safety field
17m