XUSL4E2BB051N
Code: 1759515
Code: 1759515
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Number of contact energized outputs with signalling function
0
Fade-out possible
No
Number of protected contact energized outputs
0
Type of switching output of the OSSD
PNP/PNP
Type of interface for safety communication
Other
Operation agent-safety class
Safety class 3
Type of electric connection
Connector M12
With beam coding
No
Number of protected semiconductor outputs
2
Detection capability for test bodies
0mm
Reduced resolution
Yes
Safety field height
510mm
Length of sensor
31mm
Voltage type
AC/DC
Explosion safety category for gas
None
Rated control supply voltage Us at DC
24 - 24V
Override possible
No
Scope of delivery of the one-way system
Transmitter and receiver
Resolution of the light curtain
0mm
With muting function
Yes
Ambient temperature
-10 - 55°C
Number of semiconductor outputs with signalling function
0
Cascadable
No
Width sensor
29.4mm
With monitoring function downstream switching devices
No
Response time
2.5ms
Explosion safety category for dust
None
Max. output current at protected output
400mA
Type of safety according to IEC 61496-1
4
Height of sensor
677mm
With restart blockage
Yes
Suitable for safety functions
Yes
Switching voltage of OSSD at state "high"
24V
Wavelength of the sensor
950nm
Degree of protection (IP)
IP65
Transmission range of the safety field
12m
Clock control possible
No
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL4E2BB051N
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Number of contact energized outputs with signalling function
0
Fade-out possible
Number of protected contact energized outputs
0
Type of switching output of the OSSD
PNP/PNP
Type of interface for safety communication
Other
Operation agent-safety class
Safety class 3
Type of electric connection
Connector M12
With beam coding
Number of protected semiconductor outputs
2
Detection capability for test bodies
0mm
Reduced resolution
Safety field height
510mm
Length of sensor
31mm
Voltage type
AC/DC
Explosion safety category for gas
None
Rated control supply voltage Us at DC
24 .. 24V
Override possible
Scope of delivery of the one-way system
Transmitter and receiver
Resolution of the light curtain
0mm
With muting function
Ambient temperature
-10 .. 55°C
Number of semiconductor outputs with signalling function
0
Cascadable
Width sensor
29.4mm
With monitoring function downstream switching devices
Response time
2.5ms
Explosion safety category for dust
None
Max. output current at protected output
400mA
Type of safety according to IEC 61496-1
4
Height of sensor
677mm
With restart blockage
Suitable for safety functions
Switching voltage of OSSD at state "high"
24V
Wavelength of the sensor
950nm
Degree of protection (IP)
IP65
Transmission range of the safety field
12m
Clock control possible
We use cookies to enhance your experience.