XUSL4E14F151N
Code: 1759509
Code: 1759509
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Number of protected semiconductor outputs
2
Number of contact energized outputs with signalling function
0
Resolution of the light curtain
14mm
Type of interface for safety communication
Other
Explosion safety category for gas
None
Height of sensor
150mm
Cascadable
No
Switching voltage of OSSD at state "high"
24V
Voltage type
AC/DC
Wavelength of the sensor
950nm
Clock control possible
No
Type of switching output of the OSSD
PNP/PNP
With monitoring function downstream switching devices
No
Suitable for safety functions
Yes
Degree of protection (IP)
IP65
With restart blockage
Yes
Type of electric connection
Connector M12
Number of protected contact energized outputs
0
Detection capability for test bodies
14mm
Length of sensor
31mm
Width sensor
29.4mm
Override possible
No
Ambient temperature
-10 - 55°C
Number of semiconductor outputs with signalling function
0
Scope of delivery of the one-way system
Transmitter and receiver
Max. output current at protected output
400mA
Explosion safety category for dust
None
Response time
20ms
Fade-out possible
No
Safety field height
1510mm
Rated control supply voltage Us at DC
24 - 24V
Transmission range of the safety field
6m
With beam coding
No
Operation agent-safety class
Safety class 3
Type of safety according to IEC 61496-1
4
With muting function
Yes
Reduced resolution
No
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL4E14F151N
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Number of protected semiconductor outputs
2
Number of contact energized outputs with signalling function
0
Resolution of the light curtain
14mm
Type of interface for safety communication
Other
Explosion safety category for gas
None
Height of sensor
150mm
Cascadable
Switching voltage of OSSD at state "high"
24V
Voltage type
AC/DC
Wavelength of the sensor
950nm
Clock control possible
Type of switching output of the OSSD
PNP/PNP
With monitoring function downstream switching devices
Suitable for safety functions
Degree of protection (IP)
IP65
With restart blockage
Type of electric connection
Connector M12
Number of protected contact energized outputs
0
Detection capability for test bodies
14mm
Length of sensor
31mm
Width sensor
29.4mm
Override possible
Ambient temperature
-10 .. 55°C
Number of semiconductor outputs with signalling function
0
Scope of delivery of the one-way system
Transmitter and receiver
Max. output current at protected output
400mA
Explosion safety category for dust
None
Response time
20ms
Fade-out possible
Safety field height
1510mm
Rated control supply voltage Us at DC
24 .. 24V
Transmission range of the safety field
6m
With beam coding
Operation agent-safety class
Safety class 3
Type of safety according to IEC 61496-1
4
With muting function
Reduced resolution