XUSL4E14F121N
Code: 1759507
Code: 1759507
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Number of protected contact energized outputs
0
Number of protected semiconductor outputs
2
Type of interface for safety communication
Other
Operation agent-safety class
Safety class 3
Height of sensor
120mm
Type of switching output of the OSSD
PNP/PNP
Length of sensor
31mm
Detection capability for test bodies
14mm
Explosion safety category for dust
None
Width sensor
29.4mm
Cascadable
No
Ambient temperature
-10 - 55°C
Max. output current at protected output
400mA
Response time
16.5ms
Switching voltage of OSSD at state "high"
24V
Resolution of the light curtain
14mm
Transmission range of the safety field
6m
Type of safety according to IEC 61496-1
4
Number of semiconductor outputs with signalling function
0
Explosion safety category for gas
None
Reduced resolution
No
Voltage type
AC/DC
Type of electric connection
Connector M12
Wavelength of the sensor
950nm
With muting function
Yes
Number of contact energized outputs with signalling function
0
Fade-out possible
No
Scope of delivery of the one-way system
Transmitter and receiver
Rated control supply voltage Us at DC
24 - 24V
Override possible
No
Safety field height
1210mm
With monitoring function downstream switching devices
No
Clock control possible
No
Degree of protection (IP)
IP65
With restart blockage
Yes
Suitable for safety functions
Yes
With beam coding
No
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL4E14F121N
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Number of protected contact energized outputs
0
Number of protected semiconductor outputs
2
Type of interface for safety communication
Other
Operation agent-safety class
Safety class 3
Height of sensor
120mm
Type of switching output of the OSSD
PNP/PNP
Length of sensor
31mm
Detection capability for test bodies
14mm
Explosion safety category for dust
None
Width sensor
29.4mm
Cascadable
Ambient temperature
-10 .. 55°C
Max. output current at protected output
400mA
Response time
16.5ms
Switching voltage of OSSD at state "high"
24V
Resolution of the light curtain
14mm
Transmission range of the safety field
6m
Type of safety according to IEC 61496-1
4
Number of semiconductor outputs with signalling function
0
Explosion safety category for gas
None
Reduced resolution
Voltage type
AC/DC
Type of electric connection
Connector M12
Wavelength of the sensor
950nm
With muting function
Number of contact energized outputs with signalling function
0
Fade-out possible
Scope of delivery of the one-way system
Transmitter and receiver
Rated control supply voltage Us at DC
24 .. 24V
Override possible
Safety field height
1210mm
With monitoring function downstream switching devices
Clock control possible
Degree of protection (IP)
IP65
With restart blockage
Suitable for safety functions
With beam coding