XUSL4E14F061NS2
Code: 1759496
Code: 1759496
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Response time
-ms
Type of switching output of the OSSD
PNP/PNP
Detection capability for test bodies
14mm
Height of sensor
687mm
Resolution of the light curtain
14mm
Ambient temperature
-10 - 55°C
With beam coding
No
Wavelength of the sensor
950nm
Degree of protection (IP)
IP65
Clock control possible
No
Rated control supply voltage Us at DC
24 - 24V
Width sensor
29.4mm
Number of contact energized outputs with signalling function
0
Type of electric connection
Connector M12
Number of protected semiconductor outputs
2
Number of protected contact energized outputs
0
Type of interface for safety communication
Other
Explosion safety category for gas
None
Operation agent-safety class
Safety class 3
Fade-out possible
No
Number of semiconductor outputs with signalling function
0
Switching voltage of OSSD at state "high"
24V
Scope of delivery of the one-way system
Transmitter and receiver
Max. output current at protected output
400mA
Explosion safety category for dust
None
Cascadable
Yes
With muting function
Yes
Length of sensor
31mm
With restart blockage
Yes
Reduced resolution
No
Override possible
No
Voltage type
AC/DC
Safety field height
610mm
With monitoring function downstream switching devices
No
Suitable for safety functions
Yes
Transmission range of the safety field
6m
Type of safety according to IEC 61496-1
4
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL4E14F061NS2
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Response time
-ms
Type of switching output of the OSSD
PNP/PNP
Detection capability for test bodies
14mm
Height of sensor
687mm
Resolution of the light curtain
14mm
Ambient temperature
-10 .. 55°C
With beam coding
Wavelength of the sensor
950nm
Degree of protection (IP)
IP65
Clock control possible
Rated control supply voltage Us at DC
24 .. 24V
Width sensor
29.4mm
Number of contact energized outputs with signalling function
0
Type of electric connection
Connector M12
Number of protected semiconductor outputs
2
Number of protected contact energized outputs
0
Type of interface for safety communication
Other
Explosion safety category for gas
None
Operation agent-safety class
Safety class 3
Fade-out possible
Number of semiconductor outputs with signalling function
0
Switching voltage of OSSD at state "high"
24V
Scope of delivery of the one-way system
Transmitter and receiver
Max. output current at protected output
400mA
Explosion safety category for dust
None
Cascadable
With muting function
Length of sensor
31mm
With restart blockage
Reduced resolution
Override possible
Voltage type
AC/DC
Safety field height
610mm
With monitoring function downstream switching devices
Suitable for safety functions
Transmission range of the safety field
6m
Type of safety according to IEC 61496-1
4