XUSL4E14F061NM
Code: 1759494
Code: 1759494
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Response time
-ms
Type of switching output of the OSSD
PNP/PNP
Number of contact energized outputs with signalling function
0
Explosion safety category for gas
None
Height of sensor
687mm
Resolution of the light curtain
14mm
Switching voltage of OSSD at state "high"
24V
Override possible
No
With muting function
Yes
Explosion safety category for dust
None
Number of semiconductor outputs with signalling function
0
Number of protected semiconductor outputs
2
Type of interface for safety communication
Other
Safety field height
610mm
Length of sensor
31mm
Cascadable
Yes
Width sensor
29.4mm
Reduced resolution
No
Fade-out possible
No
Max. output current at protected output
400mA
Type of safety according to IEC 61496-1
4
Scope of delivery of the one-way system
Transmitter and receiver
Transmission range of the safety field
6m
Wavelength of the sensor
950nm
Type of electric connection
Connector M12
Rated control supply voltage Us at DC
24 - 24V
Operation agent-safety class
Safety class 3
Number of protected contact energized outputs
0
Degree of protection (IP)
IP65
Voltage type
AC/DC
Clock control possible
No
With beam coding
No
With restart blockage
Yes
Ambient temperature
-10 - 55°C
Detection capability for test bodies
14mm
Suitable for safety functions
Yes
With monitoring function downstream switching devices
No
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL4E14F061NM
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Response time
-ms
Type of switching output of the OSSD
PNP/PNP
Number of contact energized outputs with signalling function
0
Explosion safety category for gas
None
Height of sensor
687mm
Resolution of the light curtain
14mm
Switching voltage of OSSD at state "high"
24V
Override possible
With muting function
Explosion safety category for dust
None
Number of semiconductor outputs with signalling function
0
Number of protected semiconductor outputs
2
Type of interface for safety communication
Other
Safety field height
610mm
Length of sensor
31mm
Cascadable
Width sensor
29.4mm
Reduced resolution
Fade-out possible
Max. output current at protected output
400mA
Type of safety according to IEC 61496-1
4
Scope of delivery of the one-way system
Transmitter and receiver
Transmission range of the safety field
6m
Wavelength of the sensor
950nm
Type of electric connection
Connector M12
Rated control supply voltage Us at DC
24 .. 24V
Operation agent-safety class
Safety class 3
Number of protected contact energized outputs
0
Degree of protection (IP)
IP65
Voltage type
AC/DC
Clock control possible
With beam coding
With restart blockage
Ambient temperature
-10 .. 55°C
Detection capability for test bodies
14mm
Suitable for safety functions
With monitoring function downstream switching devices
We use cookies to enhance your experience.