XUSL4E14F046NWC
Code: 1759491
Code: 1759491
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Number of protected semiconductor outputs
2
Number of semiconductor outputs with signalling function
0
Number of protected contact energized outputs
0
Fade-out possible
No
Type of switching output of the OSSD
PNP/PNP
Operation agent-safety class
Safety class 3
Number of contact energized outputs with signalling function
0
Height of sensor
620mm
Type of electric connection
Connector M12
Width sensor
75mm
Length of sensor
76mm
Explosion safety category for gas
None
Explosion safety category for dust
None
Detection capability for test bodies
14mm
Max. output current at protected output
400mA
Cascadable
No
Type of interface for safety communication
Other
Ambient temperature
-10 - 55°C
Safety field height
460mm
Transmission range of the safety field
5m
Voltage type
AC/DC
Clock control possible
No
Reduced resolution
No
Response time
7.5ms
Type of safety according to IEC 61496-1
4
Wavelength of the sensor
950nm
Suitable for safety functions
Yes
With beam coding
No
With monitoring function downstream switching devices
No
With muting function
Yes
Override possible
No
Rated control supply voltage Us at DC
24 - 24V
Resolution of the light curtain
14mm
Switching voltage of OSSD at state "high"
24V
Scope of delivery of the one-way system
Transmitter and receiver
Degree of protection (IP)
IP65
With restart blockage
Yes
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL4E14F046NWC
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Number of protected semiconductor outputs
2
Number of semiconductor outputs with signalling function
0
Number of protected contact energized outputs
0
Fade-out possible
Type of switching output of the OSSD
PNP/PNP
Operation agent-safety class
Safety class 3
Number of contact energized outputs with signalling function
0
Height of sensor
620mm
Type of electric connection
Connector M12
Width sensor
75mm
Length of sensor
76mm
Explosion safety category for gas
None
Explosion safety category for dust
None
Detection capability for test bodies
14mm
Max. output current at protected output
400mA
Cascadable
Type of interface for safety communication
Other
Ambient temperature
-10 .. 55°C
Safety field height
460mm
Transmission range of the safety field
5m
Voltage type
AC/DC
Clock control possible
Reduced resolution
Response time
7.5ms
Type of safety according to IEC 61496-1
4
Wavelength of the sensor
950nm
Suitable for safety functions
With beam coding
With monitoring function downstream switching devices
With muting function
Override possible
Rated control supply voltage Us at DC
24 .. 24V
Resolution of the light curtain
14mm
Switching voltage of OSSD at state "high"
24V
Scope of delivery of the one-way system
Transmitter and receiver
Degree of protection (IP)
IP65
With restart blockage