XUSL4E14F046NS1
Code: 1759489
Code: 1759489
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Response time
-ms
Number of semiconductor outputs with signalling function
0
Number of protected semiconductor outputs
2
Length of sensor
31mm
Number of contact energized outputs with signalling function
0
Operation agent-safety class
Safety class 3
Width sensor
29.4mm
Height of sensor
513mm
Ambient temperature
-10 - 55°C
Switching voltage of OSSD at state "high"
24V
With beam coding
No
Resolution of the light curtain
14mm
With restart blockage
Yes
Voltage type
AC/DC
Suitable for safety functions
Yes
With monitoring function downstream switching devices
No
Override possible
No
Type of interface for safety communication
Other
Type of electric connection
Connector M12
Explosion safety category for dust
None
Transmission range of the safety field
6m
Detection capability for test bodies
14mm
Scope of delivery of the one-way system
Transmitter and receiver
Rated control supply voltage Us at DC
24 - 24V
With muting function
Yes
Number of protected contact energized outputs
0
Safety field height
460mm
Reduced resolution
No
Explosion safety category for gas
None
Clock control possible
No
Max. output current at protected output
400mA
Degree of protection (IP)
IP65
Type of safety according to IEC 61496-1
4
Wavelength of the sensor
950nm
Type of switching output of the OSSD
PNP/PNP
Fade-out possible
No
Cascadable
Yes
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL4E14F046NS1
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Response time
-ms
Number of semiconductor outputs with signalling function
0
Number of protected semiconductor outputs
2
Length of sensor
31mm
Number of contact energized outputs with signalling function
0
Operation agent-safety class
Safety class 3
Width sensor
29.4mm
Height of sensor
513mm
Ambient temperature
-10 .. 55°C
Switching voltage of OSSD at state "high"
24V
With beam coding
Resolution of the light curtain
14mm
With restart blockage
Voltage type
AC/DC
Suitable for safety functions
With monitoring function downstream switching devices
Override possible
Type of interface for safety communication
Other
Type of electric connection
Connector M12
Explosion safety category for dust
None
Transmission range of the safety field
6m
Detection capability for test bodies
14mm
Scope of delivery of the one-way system
Transmitter and receiver
Rated control supply voltage Us at DC
24 .. 24V
With muting function
Number of protected contact energized outputs
0
Safety field height
460mm
Reduced resolution
Explosion safety category for gas
None
Clock control possible
Max. output current at protected output
400mA
Degree of protection (IP)
IP65
Type of safety according to IEC 61496-1
4
Wavelength of the sensor
950nm
Type of switching output of the OSSD
PNP/PNP
Fade-out possible
Cascadable
We use cookies to enhance your experience.