XUSL2E4BB091N
Code: 1759480
Code: 1759480
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Fade-out possible
No
Type of interface for safety communication
Other
Height of sensor
1077mm
Explosion safety category for gas
None
Explosion safety category for dust
None
Number of protected contact energized outputs
0
Switching voltage of OSSD at state "high"
24V
Voltage type
AC/DC
With muting function
Yes
Max. output current at protected output
400mA
Clock control possible
No
Safety field height
910mm
Rated control supply voltage Us at DC
24 - 24V
Scope of delivery of the one-way system
Transmitter and receiver
Resolution of the light curtain
0mm
Width sensor
29.4mm
Cascadable
No
Type of switching output of the OSSD
PNP/PNP
Number of contact energized outputs with signalling function
0
Operation agent-safety class
Safety class 1
Degree of protection (IP)
IP65
Reduced resolution
Yes
With restart blockage
Yes
Wavelength of the sensor
950nm
Length of sensor
31mm
Detection capability for test bodies
0mm
Number of protected semiconductor outputs
2
Number of semiconductor outputs with signalling function
0
With beam coding
No
Transmission range of the safety field
12m
Response time
3.5ms
Type of electric connection
Connector M12
Suitable for safety functions
Yes
Override possible
No
Ambient temperature
-10 - 55°C
With monitoring function downstream switching devices
No
Type of safety according to IEC 61496-1
2
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL2E4BB091N
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Fade-out possible
Type of interface for safety communication
Other
Height of sensor
1077mm
Explosion safety category for gas
None
Explosion safety category for dust
None
Number of protected contact energized outputs
0
Switching voltage of OSSD at state "high"
24V
Voltage type
AC/DC
With muting function
Max. output current at protected output
400mA
Clock control possible
Safety field height
910mm
Rated control supply voltage Us at DC
24 .. 24V
Scope of delivery of the one-way system
Transmitter and receiver
Resolution of the light curtain
0mm
Width sensor
29.4mm
Cascadable
Type of switching output of the OSSD
PNP/PNP
Number of contact energized outputs with signalling function
0
Operation agent-safety class
Safety class 1
Degree of protection (IP)
IP65
Reduced resolution
With restart blockage
Wavelength of the sensor
950nm
Length of sensor
31mm
Detection capability for test bodies
0mm
Number of protected semiconductor outputs
2
Number of semiconductor outputs with signalling function
0
With beam coding
Transmission range of the safety field
12m
Response time
3.5ms
Type of electric connection
Connector M12
Suitable for safety functions
Override possible
Ambient temperature
-10 .. 55°C
With monitoring function downstream switching devices
Type of safety according to IEC 61496-1
2