XUSL2E3BB081N
Code: 1759479
Code: 1759479
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Number of contact energized outputs with signalling function
0
Type of switching output of the OSSD
PNP/PNP
Number of semiconductor outputs with signalling function
0
Operation agent-safety class
Safety class 1
Height of sensor
977mm
Width sensor
29.4mm
Type of electric connection
Connector M12
Detection capability for test bodies
0mm
Explosion safety category for dust
None
Scope of delivery of the one-way system
Transmitter and receiver
Response time
3.5ms
Override possible
No
Resolution of the light curtain
0mm
Explosion safety category for gas
None
Number of protected semiconductor outputs
2
Length of sensor
31mm
Number of protected contact energized outputs
0
Type of interface for safety communication
Other
Fade-out possible
No
Ambient temperature
-10 - 55°C
Max. output current at protected output
400mA
With muting function
Yes
Cascadable
No
Voltage type
AC/DC
Clock control possible
No
Suitable for safety functions
Yes
With beam coding
No
Degree of protection (IP)
IP65
With monitoring function downstream switching devices
No
With restart blockage
Yes
Wavelength of the sensor
950nm
Reduced resolution
Yes
Type of safety according to IEC 61496-1
2
Switching voltage of OSSD at state "high"
24V
Rated control supply voltage Us at DC
24 - 24V
Transmission range of the safety field
12m
Safety field height
810mm
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL2E3BB081N
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Number of contact energized outputs with signalling function
0
Type of switching output of the OSSD
PNP/PNP
Number of semiconductor outputs with signalling function
0
Operation agent-safety class
Safety class 1
Height of sensor
977mm
Width sensor
29.4mm
Type of electric connection
Connector M12
Detection capability for test bodies
0mm
Explosion safety category for dust
None
Scope of delivery of the one-way system
Transmitter and receiver
Response time
3.5ms
Override possible
Resolution of the light curtain
0mm
Explosion safety category for gas
None
Number of protected semiconductor outputs
2
Length of sensor
31mm
Number of protected contact energized outputs
0
Type of interface for safety communication
Other
Fade-out possible
Ambient temperature
-10 .. 55°C
Max. output current at protected output
400mA
With muting function
Cascadable
Voltage type
AC/DC
Clock control possible
Suitable for safety functions
With beam coding
Degree of protection (IP)
IP65
With monitoring function downstream switching devices
With restart blockage
Wavelength of the sensor
950nm
Reduced resolution
Type of safety according to IEC 61496-1
2
Switching voltage of OSSD at state "high"
24V
Rated control supply voltage Us at DC
24 .. 24V
Transmission range of the safety field
12m
Safety field height
810mm
We use cookies to enhance your experience.