XUSL2E30H091NWH
Code: 1759470
Code: 1759470
Rated control supply voltage Us at AC 60HZ
- - -V
Rated control supply voltage Us at AC 50HZ
- - -V
Number of protected semiconductor outputs
2
Detection capability for test bodies
30mm
Fade-out possible
No
Rated control supply voltage Us at DC
24 - 24V
Override possible
No
Ambient temperature
-25 - 55°C
Resolution of the light curtain
30mm
Transmission range of the safety field
10m
Number of protected contact energized outputs
0
Switching voltage of OSSD at state "high"
24V
Height of sensor
1070mm
Explosion safety category for gas
None
Operation agent-safety class
Safety class 1
Length of sensor
76mm
Width sensor
75mm
Type of interface for safety communication
Other
Type of switching output of the OSSD
PNP/PNP
With muting function
Yes
Scope of delivery of the one-way system
Transmitter and receiver
Safety field height
910mm
With beam coding
No
Explosion safety category for dust
None
Voltage type
AC/DC
Cascadable
No
Number of semiconductor outputs with signalling function
0
Type of safety according to IEC 61496-1
2
Max. output current at protected output
400mA
Response time
13ms
Number of contact energized outputs with signalling function
0
Type of electric connection
Connector M12
Suitable for safety functions
Yes
Clock control possible
No
Wavelength of the sensor
950nm
With restart blockage
Yes
With monitoring function downstream switching devices
No
Degree of protection (IP)
IP65
Reduced resolution
No
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL2E30H091NWH
Rated control supply voltage Us at AC 60HZ
- .. -V
Rated control supply voltage Us at AC 50HZ
- .. -V
Number of protected semiconductor outputs
2
Detection capability for test bodies
30mm
Fade-out possible
Rated control supply voltage Us at DC
24 .. 24V
Override possible
Ambient temperature
-25 .. 55°C
Resolution of the light curtain
30mm
Transmission range of the safety field
10m
Number of protected contact energized outputs
0
Switching voltage of OSSD at state "high"
24V
Height of sensor
1070mm
Explosion safety category for gas
None
Operation agent-safety class
Safety class 1
Length of sensor
76mm
Width sensor
75mm
Type of interface for safety communication
Other
Type of switching output of the OSSD
PNP/PNP
With muting function
Scope of delivery of the one-way system
Transmitter and receiver
Safety field height
910mm
With beam coding
Explosion safety category for dust
None
Voltage type
AC/DC
Cascadable
Number of semiconductor outputs with signalling function
0
Type of safety according to IEC 61496-1
2
Max. output current at protected output
400mA
Response time
13ms
Number of contact energized outputs with signalling function
0
Type of electric connection
Connector M12
Suitable for safety functions
Clock control possible
Wavelength of the sensor
950nm
With restart blockage
With monitoring function downstream switching devices
Degree of protection (IP)
IP65
Reduced resolution