XUSL2E30H076NWC
Code: 1759466
Code: 1759466
Rated control supply voltage Us at AC 60HZ
- - -V
Rated control supply voltage Us at AC 50HZ
- - -V
Number of semiconductor outputs with signalling function
0
Length of sensor
76mm
Response time
11ms
Explosion safety category for gas
None
Override possible
No
Ambient temperature
-10 - 55°C
Type of electric connection
Connector M12
Height of sensor
920mm
Detection capability for test bodies
30mm
Type of safety according to IEC 61496-1
2
Scope of delivery of the one-way system
Transmitter and receiver
Number of contact energized outputs with signalling function
0
Explosion safety category for dust
None
Cascadable
No
Max. output current at protected output
400mA
Resolution of the light curtain
30mm
Transmission range of the safety field
10m
Rated control supply voltage Us at DC
24 - 24V
With beam coding
No
Safety field height
760mm
Degree of protection (IP)
IP65
With muting function
Yes
Fade-out possible
No
Suitable for safety functions
Yes
Width sensor
75mm
Switching voltage of OSSD at state "high"
24V
Number of protected semiconductor outputs
2
With monitoring function downstream switching devices
No
Clock control possible
No
Operation agent-safety class
Safety class 1
With restart blockage
Yes
Voltage type
AC/DC
Type of switching output of the OSSD
PNP/PNP
Reduced resolution
No
Type of interface for safety communication
Other
Number of protected contact energized outputs
0
Wavelength of the sensor
950nm
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL2E30H076NWC
Rated control supply voltage Us at AC 60HZ
- .. -V
Rated control supply voltage Us at AC 50HZ
- .. -V
Number of semiconductor outputs with signalling function
0
Length of sensor
76mm
Response time
11ms
Explosion safety category for gas
None
Override possible
Ambient temperature
-10 .. 55°C
Type of electric connection
Connector M12
Height of sensor
920mm
Detection capability for test bodies
30mm
Type of safety according to IEC 61496-1
2
Scope of delivery of the one-way system
Transmitter and receiver
Number of contact energized outputs with signalling function
0
Explosion safety category for dust
None
Cascadable
Max. output current at protected output
400mA
Resolution of the light curtain
30mm
Transmission range of the safety field
10m
Rated control supply voltage Us at DC
24 .. 24V
With beam coding
Safety field height
760mm
Degree of protection (IP)
IP65
With muting function
Fade-out possible
Suitable for safety functions
Width sensor
75mm
Switching voltage of OSSD at state "high"
24V
Number of protected semiconductor outputs
2
With monitoring function downstream switching devices
Clock control possible
Operation agent-safety class
Safety class 1
With restart blockage
Voltage type
AC/DC
Type of switching output of the OSSD
PNP/PNP
Reduced resolution
Type of interface for safety communication
Other
Number of protected contact energized outputs
0
Wavelength of the sensor
950nm
We use cookies to enhance your experience.