XUSL2E30H061NWC
Code: 1759463
Code: 1759463
Rated control supply voltage Us at AC 60HZ
- - -V
Rated control supply voltage Us at AC 50HZ
- - -V
Number of semiconductor outputs with signalling function
0
Number of protected contact energized outputs
0
Type of switching output of the OSSD
PNP/PNP
Type of interface for safety communication
Other
Fade-out possible
No
Number of contact energized outputs with signalling function
0
Type of electric connection
Connector M12
Length of sensor
76mm
Detection capability for test bodies
30mm
Explosion safety category for gas
None
Width sensor
75mm
Number of protected semiconductor outputs
2
Height of sensor
770mm
Safety field height
610mm
Transmission range of the safety field
10m
Type of safety according to IEC 61496-1
2
With restart blockage
Yes
Voltage type
AC/DC
Wavelength of the sensor
950nm
Operation agent-safety class
Safety class 1
Response time
10ms
Override possible
No
Scope of delivery of the one-way system
Transmitter and receiver
Ambient temperature
-10 - 55°C
With beam coding
No
With muting function
Yes
Cascadable
No
Reduced resolution
No
Clock control possible
No
Degree of protection (IP)
IP65
Suitable for safety functions
Yes
Resolution of the light curtain
30mm
With monitoring function downstream switching devices
No
Rated control supply voltage Us at DC
24 - 24V
Explosion safety category for dust
None
Max. output current at protected output
400mA
Switching voltage of OSSD at state "high"
24V
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL2E30H061NWC
Rated control supply voltage Us at AC 60HZ
- .. -V
Rated control supply voltage Us at AC 50HZ
- .. -V
Number of semiconductor outputs with signalling function
0
Number of protected contact energized outputs
0
Type of switching output of the OSSD
PNP/PNP
Type of interface for safety communication
Other
Fade-out possible
Number of contact energized outputs with signalling function
0
Type of electric connection
Connector M12
Length of sensor
76mm
Detection capability for test bodies
30mm
Explosion safety category for gas
None
Width sensor
75mm
Number of protected semiconductor outputs
2
Height of sensor
770mm
Safety field height
610mm
Transmission range of the safety field
10m
Type of safety according to IEC 61496-1
2
With restart blockage
Voltage type
AC/DC
Wavelength of the sensor
950nm
Operation agent-safety class
Safety class 1
Response time
10ms
Override possible
Scope of delivery of the one-way system
Transmitter and receiver
Ambient temperature
-10 .. 55°C
With beam coding
With muting function
Cascadable
Reduced resolution
Clock control possible
Degree of protection (IP)
IP65
Suitable for safety functions
Resolution of the light curtain
30mm
With monitoring function downstream switching devices
Rated control supply voltage Us at DC
24 .. 24V
Explosion safety category for dust
None
Max. output current at protected output
400mA
Switching voltage of OSSD at state "high"
24V