XUSL2E30H046N
Code: 1759459
Code: 1759459
Rated control supply voltage Us at AC 60HZ
- - -V
Rated control supply voltage Us at AC 50HZ
- - -V
Number of semiconductor outputs with signalling function
0
Type of switching output of the OSSD
PNP/PNP
Fade-out possible
No
Type of interface for safety communication
Other
Operation agent-safety class
Safety class 1
Detection capability for test bodies
30mm
Length of sensor
31mm
Number of protected semiconductor outputs
2
Explosion safety category for gas
None
Cascadable
No
Type of electric connection
Connector M12
Height of sensor
513mm
Width sensor
29.4mm
Number of protected contact energized outputs
0
Number of contact energized outputs with signalling function
0
Reduced resolution
No
Safety field height
460mm
Voltage type
AC/DC
Type of safety according to IEC 61496-1
2
Ambient temperature
-10 - 55°C
Max. output current at protected output
400mA
Response time
8ms
Switching voltage of OSSD at state "high"
24V
Override possible
No
Explosion safety category for dust
None
With muting function
Yes
With restart blockage
Yes
Suitable for safety functions
Yes
Rated control supply voltage Us at DC
24 - 24V
With beam coding
No
Degree of protection (IP)
IP65
Transmission range of the safety field
12m
Resolution of the light curtain
30mm
Scope of delivery of the one-way system
Transmitter and receiver
Clock control possible
No
Wavelength of the sensor
950nm
With monitoring function downstream switching devices
No
Zagreb:
0 pcs
Zadar:
0 pcs
XUSL2E30H046N
Rated control supply voltage Us at AC 60HZ
- .. -V
Rated control supply voltage Us at AC 50HZ
- .. -V
Number of semiconductor outputs with signalling function
0
Type of switching output of the OSSD
PNP/PNP
Fade-out possible
Type of interface for safety communication
Other
Operation agent-safety class
Safety class 1
Detection capability for test bodies
30mm
Length of sensor
31mm
Number of protected semiconductor outputs
2
Explosion safety category for gas
None
Cascadable
Type of electric connection
Connector M12
Height of sensor
513mm
Width sensor
29.4mm
Number of protected contact energized outputs
0
Number of contact energized outputs with signalling function
0
Reduced resolution
Safety field height
460mm
Voltage type
AC/DC
Type of safety according to IEC 61496-1
2
Ambient temperature
-10 .. 55°C
Max. output current at protected output
400mA
Response time
8ms
Switching voltage of OSSD at state "high"
24V
Override possible
Explosion safety category for dust
None
With muting function
With restart blockage
Suitable for safety functions
Rated control supply voltage Us at DC
24 .. 24V
With beam coding
Degree of protection (IP)
IP65
Transmission range of the safety field
12m
Resolution of the light curtain
30mm
Scope of delivery of the one-way system
Transmitter and receiver
Clock control possible
Wavelength of the sensor
950nm
With monitoring function downstream switching devices
We use cookies to enhance your experience.