

Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
0 - 0V
Supply voltage AC 60 Hz
0 - 0V
Model
Compact
Processing time (1K, binary operation)
0.022ms
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces RS-485
2
Number of HW-interfaces other
0
Number of HW-interfaces RS-232
2
With optical interface
No
Supply voltage DC
19.2 - 28.8V
Max. number of time switches
0
Number of digital inputs
24
Supporting protocol for PROFIBUS
No
Number of interfaces PROFINET
0
Voltage type of supply voltage
DC
Supporting protocol for TCP/IP
Yes
Number of HW-interfaces USB
1
Number of relay outputs
0
Number of HW-interfaces Wireless
0
Supporting protocol for INTERBUS
No
Number of HW-interfaces parallel
0
Supporting protocol for CAN
No
Number of HW-interfaces RS-422
0
Number of digital outputs
16
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Number of analogue outputs
0
Supporting protocol for LON
No
Supporting protocol for DeviceNet
No
Supporting protocol for Data-Highway
No
Supporting protocol for PROFINET CBA
No
Number of analogue inputs
0
Supporting protocol for PROFINET IO
No
Supporting protocol for SUCONET
No
Supporting protocol for SERCOS
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for Modbus
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
No
Supporting protocol for IEC 61850 Ethernet
No
Supporting protocol for SafetyBUS p
No
Radio standard GPRS
No
Radio standard UMTS
No
Radio standard GSM
No
Radio standard Wi-Fi 802.11
No
Supporting protocol for IEC 60870
No
Radio standard Bluetooth
No
Supporting protocol for DNP3
No
Long-Term Evolution (LTE)
No
IO link master
No
System accessory
No
With display
No
Redundancy
No
Type of memory
NVRAM
Memory size
64000kByte
Rail mounting possible
Yes
Additional program memory possible
Yes
Wall mounting/direct mounting
Yes
Front built-in possible
No
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
No
Suitable for safety functions
No
Rack-assembly possible
No
SIL according to IEC 61508
None
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Height
90mm
Depth
95mm
Width
190mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
TM241CE40U

Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
0 .. 0V
Supply voltage AC 60 Hz
0 .. 0V
Model
Compact
Processing time (1K, binary operation)
0.022ms
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces RS-485
2
Number of HW-interfaces other
0
Number of HW-interfaces RS-232
2
With optical interface
Supply voltage DC
19.2 .. 28.8V
Max. number of time switches
0
Number of digital inputs
24
Supporting protocol for PROFIBUS
Number of interfaces PROFINET
0
Voltage type of supply voltage
DC
Supporting protocol for TCP/IP
Number of HW-interfaces USB
1
Number of relay outputs
0
Number of HW-interfaces Wireless
0
Supporting protocol for INTERBUS
Number of HW-interfaces parallel
0
Supporting protocol for CAN
Number of HW-interfaces RS-422
0
Number of digital outputs
16
Supporting protocol for ASI
Supporting protocol for KNX
Number of analogue outputs
0
Supporting protocol for LON
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Supporting protocol for PROFINET CBA
Number of analogue inputs
0
Supporting protocol for PROFINET IO
Supporting protocol for SUCONET
Supporting protocol for SERCOS
Supporting protocol for DeviceNet Safety
Supporting protocol for Foundation Fieldbus
Supporting protocol for Modbus
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for EtherNet/IP
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Supporting protocol for IEC 61850 Ethernet
Supporting protocol for SafetyBUS p
Radio standard GPRS
Radio standard UMTS
Radio standard GSM
Radio standard Wi-Fi 802.11
Supporting protocol for IEC 60870
Radio standard Bluetooth
Supporting protocol for DNP3
Long-Term Evolution (LTE)
IO link master
System accessory
With display
Redundancy
Type of memory
NVRAM
Memory size
64000kByte
Rail mounting possible
Additional program memory possible
Wall mounting/direct mounting
Front built-in possible
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
Suitable for safety functions
Rack-assembly possible
SIL according to IEC 61508
None
Appendant operation agent (Ex ib)
Explosion safety category for gas
None
Explosion safety category for dust
None
Height
90mm
Depth
95mm
Width
190mm
From same serie
We use cookies to enhance your experience.