Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Type of motor starter
Reversing starter
Number of auxiliary contacts as normally closed contact
0
With short-circuit release
No
Rated operation current at AC-3, 400 V
6.5A
Release class
CLASS 10
Rated operation current Ie
9A
Number of indicator lights
4
Type of electrical connection of main circuit
Spring clamp connection
Number of command positions
0
Ambient temperature, upper operating limit
70°C
Supporting protocol for PROFIBUS
No
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
Supporting protocol for TCP/IP
No
Supporting protocol for CAN
No
Temperature compensated overload protection
Yes
Overload release current setting
1.5 - 6.5A
Rail mounting possible
Yes
Supporting protocol for INTERBUS
No
Rated power, 460 V, 60 Hz, 3-phase
3kW
Supporting protocol for DeviceNet
No
With transformer
No
Number of auxiliary contacts as normally open contact
0
Supporting protocol for Data-Highway
No
Suitable for emergency stop
Yes
With fuse
No
Supporting protocol for ASI
No
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Rated control supply voltage Us at DC
24 - 24V
Rated operation power at AC-3, 400 V
3kW
Supporting protocol for SUCONET
No
Voltage type for actuating
DC
Degree of protection (IP)
IP20
External reset possible
Yes
Supporting protocol for Modbus
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFIsafe
No
Supporting protocol for INTERBUS-Safety
No
Width
22.6mm
Supporting protocol for other bus systems
No
Height
107.5mm
Depth
113.4mm
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for SafetyBUS p
No
From same serie
LZ8H6X53BD

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Type of motor starter
Reversing starter
Number of auxiliary contacts as normally closed contact
0
With short-circuit release
Rated operation current at AC-3, 400 V
6.5A
Release class
CLASS 10
Rated operation current Ie
9A
Number of indicator lights
4
Type of electrical connection of main circuit
Spring clamp connection
Number of command positions
0
Ambient temperature, upper operating limit
70°C
Supporting protocol for PROFIBUS
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
Supporting protocol for TCP/IP
Supporting protocol for CAN
Temperature compensated overload protection
Overload release current setting
1.5 .. 6.5A
Rail mounting possible
Supporting protocol for INTERBUS
Rated power, 460 V, 60 Hz, 3-phase
3kW
Supporting protocol for DeviceNet
With transformer
Number of auxiliary contacts as normally open contact
0
Supporting protocol for Data-Highway
Suitable for emergency stop
With fuse
Supporting protocol for ASI
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Rated control supply voltage Us at DC
24 .. 24V
Rated operation power at AC-3, 400 V
3kW
Supporting protocol for SUCONET
Voltage type for actuating
DC
Degree of protection (IP)
IP20
External reset possible
Supporting protocol for Modbus
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet Safety
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFIsafe
Supporting protocol for INTERBUS-Safety
Width
22.6mm
Supporting protocol for other bus systems
Height
107.5mm
Depth
113.4mm
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for SafetyBUS p
From same serie
We use cookies to enhance your experience.