Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP20
Width
22.6mm
Depth
113.4mm
Height
106.5mm
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Overload release current setting
0.18 - 2.4A
Type of electrical connection of main circuit
Screw connection
Rated control supply voltage Us at DC
- - -V
Rated control supply voltage Us at AC 50HZ
110 - 230V
Rated control supply voltage Us at AC 60HZ
110 - 230V
Rated operation power at AC-3, 400 V
0.75kW
Voltage type for actuating
AC
Supporting protocol for SERCOS
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for LON
No
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet
No
Supporting protocol for Modbus
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for ASI
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for PROFINET IO
No
Supporting protocol for CAN
No
Supporting protocol for Data-Highway
No
Supporting protocol for INTERBUS
No
Supporting protocol for other bus systems
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for PROFIsafe
No
Number of command positions
0
Supporting protocol for DeviceNet Safety
No
Supporting protocol for SafetyBUS p
No
Suitable for emergency stop
Yes
Release class
CLASS 10
Number of indicator lights
4
Rail mounting possible
Yes
Rated operation current Ie
2.4A
Ambient temperature, upper operating limit
70°C
Rated power, 460 V, 60 Hz, 3-phase
0.75kW
Rated operation current at AC-3, 400 V
2.4A
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
With short-circuit release
No
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Temperature compensated overload protection
Yes
Type of motor starter
Reversing starter
Type of electrical connection for auxiliary- and control current circuit
Screw connection
External reset possible
Yes
With fuse
No
With transformer
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LZ8H2X4FU

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP20
Width
22.6mm
Depth
113.4mm
Height
106.5mm
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Overload release current setting
0.18 .. 2.4A
Type of electrical connection of main circuit
Screw connection
Rated control supply voltage Us at DC
- .. -V
Rated control supply voltage Us at AC 50HZ
110 .. 230V
Rated control supply voltage Us at AC 60HZ
110 .. 230V
Rated operation power at AC-3, 400 V
0.75kW
Voltage type for actuating
AC
Supporting protocol for SERCOS
Supporting protocol for INTERBUS-Safety
Supporting protocol for Foundation Fieldbus
Supporting protocol for LON
Supporting protocol for SUCONET
Supporting protocol for DeviceNet
Supporting protocol for Modbus
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for ASI
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Supporting protocol for PROFINET IO
Supporting protocol for CAN
Supporting protocol for Data-Highway
Supporting protocol for INTERBUS
Supporting protocol for other bus systems
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFIsafe
Number of command positions
0
Supporting protocol for DeviceNet Safety
Supporting protocol for SafetyBUS p
Suitable for emergency stop
Release class
CLASS 10
Number of indicator lights
4
Rail mounting possible
Rated operation current Ie
2.4A
Ambient temperature, upper operating limit
70°C
Rated power, 460 V, 60 Hz, 3-phase
0.75kW
Rated operation current at AC-3, 400 V
2.4A
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
With short-circuit release
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Temperature compensated overload protection
Type of motor starter
Reversing starter
Type of electrical connection for auxiliary- and control current circuit
Screw connection
External reset possible
With fuse
With transformer
From same serie