Aleta.hr
Main Product Image

LZ8H2X4BD

Code: 1758385

ManufacturerRAZNO
Catalog numberLZ8H2X4BD
Type
EAN code3606485421094

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 50HZ

- - -V

Rated control supply voltage Us at AC 60HZ

- - -V

Rated conditional short-circuit current, type 2, 400 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

With short-circuit release

No

Type of motor starter

Reversing starter

Rated control supply voltage Us at DC

24 - 24V

Number of auxiliary contacts as normally closed contact

0

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Rated operation power at AC-3, 400 V

0.75kW

Rated operation current at AC-3, 400 V

2.4A

Voltage type for actuating

DC

Overload release current setting

0.18 - 2.4A

Rated power, 460 V, 60 Hz, 3-phase

0.75kW

Rated operation current Ie

2.4A

Number of auxiliary contacts as normally open contact

0

Rail mounting possible

Yes

Release class

CLASS 10

Type of electrical connection of main circuit

Screw connection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Ambient temperature, upper operating limit

70°C

Temperature compensated overload protection

Yes

Number of command positions

0

With transformer

No

Suitable for emergency stop

Yes

Number of indicator lights

4

External reset possible

Yes

With fuse

No

Supporting protocol for TCP/IP

No

Degree of protection (IP)

IP20

Supporting protocol for PROFIBUS

No

Supporting protocol for INTERBUS

No

Supporting protocol for ASI

No

Supporting protocol for CAN

No

Supporting protocol for Data-Highway

No

Supporting protocol for Modbus

No

Supporting protocol for LON

No

Supporting protocol for DeviceNet

No

Supporting protocol for SUCONET

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for PROFINET IO

No

Supporting protocol for SERCOS

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for PROFIsafe

No

Supporting protocol for other bus systems

No

Width

22.6mm

Supporting protocol for SafetyBUS p

No

Supporting protocol for INTERBUS-Safety

No

Height

106.5mm

Depth

113.4mm


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

LZ8H2X4BD

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 50HZ

- .. -V

Rated control supply voltage Us at AC 60HZ

- .. -V

Rated conditional short-circuit current, type 2, 400 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

With short-circuit release

Type of motor starter

Reversing starter

Rated control supply voltage Us at DC

24 .. 24V

Number of auxiliary contacts as normally closed contact

0

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Rated operation power at AC-3, 400 V

0.75kW

Rated operation current at AC-3, 400 V

2.4A

Voltage type for actuating

DC

Overload release current setting

0.18 .. 2.4A

Rated power, 460 V, 60 Hz, 3-phase

0.75kW

Rated operation current Ie

2.4A

Number of auxiliary contacts as normally open contact

0

Rail mounting possible

Release class

CLASS 10

Type of electrical connection of main circuit

Screw connection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Ambient temperature, upper operating limit

70°C

Temperature compensated overload protection

Number of command positions

0

With transformer

Suitable for emergency stop

Number of indicator lights

4

External reset possible

With fuse

Supporting protocol for TCP/IP

Degree of protection (IP)

IP20

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for LON

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for SERCOS

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIsafe

Supporting protocol for other bus systems

Width

22.6mm

Supporting protocol for SafetyBUS p

Supporting protocol for INTERBUS-Safety

Height

106.5mm

Depth

113.4mm

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.