Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Type of motor starter
Reversing starter
With short-circuit release
No
Temperature compensated overload protection
Yes
With transformer
No
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Overload release current setting
0.18 - 2.4A
Suitable for emergency stop
Yes
Rated control supply voltage Us at DC
24 - 24V
Rated power, 460 V, 60 Hz, 3-phase
0.75kW
Rated operation current Ie
2.4A
Rated operation current at AC-3, 400 V
2.4A
Ambient temperature, upper operating limit
70°C
Voltage type for actuating
DC
Type of electrical connection of main circuit
Spring clamp connection
Rated operation power at AC-3, 400 V
0.75kW
Release class
CLASS 10
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
External reset possible
Yes
Rail mounting possible
Yes
Number of command positions
0
With fuse
No
Degree of protection (IP)
IP20
Number of indicator lights
4
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for TCP/IP
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for Modbus
No
Supporting protocol for DeviceNet
No
Supporting protocol for Data-Highway
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for PROFIsafe
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for other bus systems
No
Width
22.6mm
Height
107.5mm
Depth
113.4mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LZ8H2X43BD

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Type of motor starter
Reversing starter
With short-circuit release
Temperature compensated overload protection
With transformer
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Overload release current setting
0.18 .. 2.4A
Suitable for emergency stop
Rated control supply voltage Us at DC
24 .. 24V
Rated power, 460 V, 60 Hz, 3-phase
0.75kW
Rated operation current Ie
2.4A
Rated operation current at AC-3, 400 V
2.4A
Ambient temperature, upper operating limit
70°C
Voltage type for actuating
DC
Type of electrical connection of main circuit
Spring clamp connection
Rated operation power at AC-3, 400 V
0.75kW
Release class
CLASS 10
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
External reset possible
Rail mounting possible
Number of command positions
0
With fuse
Degree of protection (IP)
IP20
Number of indicator lights
4
Supporting protocol for PROFIBUS
Supporting protocol for CAN
Supporting protocol for TCP/IP
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for Foundation Fieldbus
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe
Supporting protocol for INTERBUS-Safety
Supporting protocol for other bus systems
Width
22.6mm
Height
107.5mm
Depth
113.4mm
From same serie
We use cookies to enhance your experience.