Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Type of motor starter
Direct online starter (DOL)
With short-circuit release
No
Voltage type for actuating
DC
Rated control supply voltage Us at DC
24 - 24V
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Rated operation power at AC-3, 400 V
3kW
Number of auxiliary contacts as normally closed contact
0
Ambient temperature, upper operating limit
70°C
Number of auxiliary contacts as normally open contact
0
Release class
CLASS 10
Temperature compensated overload protection
Yes
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
Rail mounting possible
Yes
With transformer
No
External reset possible
Yes
Suitable for emergency stop
Yes
Number of command positions
0
Number of indicator lights
3
Supporting protocol for TCP/IP
No
With fuse
No
Degree of protection (IP)
IP20
Type of electrical connection of main circuit
Spring clamp connection
Supporting protocol for PROFIBUS
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for Modbus
No
Rated operation current Ie
9A
Supporting protocol for SUCONET
No
Supporting protocol for PROFINET IO
No
Rated power, 460 V, 60 Hz, 3-phase
3kW
Supporting protocol for LON
No
Supporting protocol for EtherNet/IP
No
Rated operation current at AC-3, 400 V
6.5A
Overload release current setting
1.5 - 6.5A
Supporting protocol for PROFINET CBA
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for other bus systems
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for PROFIsafe
No
Width
22.6mm
Supporting protocol for DeviceNet Safety
No
Depth
113.4mm
Height
107.5mm
Supporting protocol for SERCOS
No
Supporting protocol for DeviceNet
No
Supporting protocol for CAN
No
Supporting protocol for Data-Highway
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LZ7H6X53BD

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Type of motor starter
Direct online starter (DOL)
With short-circuit release
Voltage type for actuating
DC
Rated control supply voltage Us at DC
24 .. 24V
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Rated operation power at AC-3, 400 V
3kW
Number of auxiliary contacts as normally closed contact
0
Ambient temperature, upper operating limit
70°C
Number of auxiliary contacts as normally open contact
0
Release class
CLASS 10
Temperature compensated overload protection
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
Rail mounting possible
With transformer
External reset possible
Suitable for emergency stop
Number of command positions
0
Number of indicator lights
3
Supporting protocol for TCP/IP
With fuse
Degree of protection (IP)
IP20
Type of electrical connection of main circuit
Spring clamp connection
Supporting protocol for PROFIBUS
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for Modbus
Rated operation current Ie
9A
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Rated power, 460 V, 60 Hz, 3-phase
3kW
Supporting protocol for LON
Supporting protocol for EtherNet/IP
Rated operation current at AC-3, 400 V
6.5A
Overload release current setting
1.5 .. 6.5A
Supporting protocol for PROFINET CBA
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for other bus systems
Supporting protocol for INTERBUS-Safety
Supporting protocol for Foundation Fieldbus
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe
Width
22.6mm
Supporting protocol for DeviceNet Safety
Depth
113.4mm
Height
107.5mm
Supporting protocol for SERCOS
Supporting protocol for DeviceNet
Supporting protocol for CAN
Supporting protocol for Data-Highway
From same serie