

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 60HZ
- - -V
Rated control supply voltage Us at AC 50HZ
- - -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
With short-circuit release
No
Type of motor starter
Reversing starter
Rated control supply voltage Us at DC
24 - 24V
Voltage type for actuating
DC
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Rated operation current at AC-3, 400 V
6.5A
Rated operation power at AC-3, 400 V
3kW
Rated power, 460 V, 60 Hz, 3-phase
3kW
Overload release current setting
1.5 - 6.5A
Number of auxiliary contacts as normally closed contact
0
Rated operation current Ie
9A
Number of auxiliary contacts as normally open contact
0
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Temperature compensated overload protection
Yes
Ambient temperature, upper operating limit
70°C
Rail mounting possible
Yes
Type of electrical connection of main circuit
Screw connection
With transformer
No
Suitable for emergency stop
No
Release class
CLASS 10
With fuse
No
Supporting protocol for TCP/IP
No
Number of command positions
0
External reset possible
Yes
Number of indicator lights
4
Supporting protocol for PROFIBUS
No
Degree of protection (IP)
IP20
Supporting protocol for CAN
No
Supporting protocol for ASI
No
Supporting protocol for INTERBUS
No
Supporting protocol for DeviceNet
No
Supporting protocol for Modbus
No
Supporting protocol for LON
No
Supporting protocol for Data-Highway
No
Supporting protocol for PROFINET IO
No
Supporting protocol for SERCOS
No
Supporting protocol for SUCONET
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for INTERBUS-Safety
No
Width
22.6mm
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Height
106.5mm
Depth
113.4mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
Code: 1758373
LZ2H6X5BD

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 60HZ
- .. -V
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
With short-circuit release
Type of motor starter
Reversing starter
Rated control supply voltage Us at DC
24 .. 24V
Voltage type for actuating
DC
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Rated operation current at AC-3, 400 V
6.5A
Rated operation power at AC-3, 400 V
3kW
Rated power, 460 V, 60 Hz, 3-phase
3kW
Overload release current setting
1.5 .. 6.5A
Number of auxiliary contacts as normally closed contact
0
Rated operation current Ie
9A
Number of auxiliary contacts as normally open contact
0
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Temperature compensated overload protection
Ambient temperature, upper operating limit
70°C
Rail mounting possible
Type of electrical connection of main circuit
Screw connection
With transformer
Suitable for emergency stop
Release class
CLASS 10
With fuse
Supporting protocol for TCP/IP
Number of command positions
0
External reset possible
Number of indicator lights
4
Supporting protocol for PROFIBUS
Degree of protection (IP)
IP20
Supporting protocol for CAN
Supporting protocol for ASI
Supporting protocol for INTERBUS
Supporting protocol for DeviceNet
Supporting protocol for Modbus
Supporting protocol for LON
Supporting protocol for Data-Highway
Supporting protocol for PROFINET IO
Supporting protocol for SERCOS
Supporting protocol for SUCONET
Supporting protocol for PROFINET CBA
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIsafe
Supporting protocol for INTERBUS-Safety
Width
22.6mm
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Height
106.5mm
Depth
113.4mm
From same serie
We use cookies to enhance your experience.