Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- - -V
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
With short-circuit release
No
Type of motor starter
Reversing starter
Rated operation power at AC-3, 400 V
0.75kW
Overload release current setting
0.18 - 2.4A
Number of auxiliary contacts as normally open contact
0
Rated power, 460 V, 60 Hz, 3-phase
0.75kW
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Rated operation current at AC-3, 400 V
2.4A
Ambient temperature, upper operating limit
70°C
Release class
CLASS 10
Temperature compensated overload protection
Yes
Voltage type for actuating
AC
Type of electrical connection of main circuit
Screw connection
Number of auxiliary contacts as normally closed contact
0
Rail mounting possible
Yes
With transformer
No
Number of indicator lights
4
Rated control supply voltage Us at AC 60HZ
110 - 230V
Rated control supply voltage Us at AC 50HZ
110 - 230V
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for TCP/IP
No
Supporting protocol for INTERBUS
No
Rated operation current Ie
2.4A
Degree of protection (IP)
IP20
With fuse
No
Supporting protocol for PROFIBUS
No
External reset possible
Yes
Supporting protocol for CAN
No
Supporting protocol for Data-Highway
No
Supporting protocol for Modbus
No
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet
No
Supporting protocol for LON
No
Supporting protocol for PROFINET CBA
No
Suitable for emergency stop
No
Supporting protocol for PROFINET IO
No
Number of command positions
0
Supporting protocol for ASI
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SERCOS
No
Supporting protocol for PROFIsafe
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for other bus systems
No
Supporting protocol for SafetyBUS p
No
Depth
113.4mm
Height
106.5mm
Width
22.6mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LZ2H2X4FU

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- .. -V
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
With short-circuit release
Type of motor starter
Reversing starter
Rated operation power at AC-3, 400 V
0.75kW
Overload release current setting
0.18 .. 2.4A
Number of auxiliary contacts as normally open contact
0
Rated power, 460 V, 60 Hz, 3-phase
0.75kW
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Rated operation current at AC-3, 400 V
2.4A
Ambient temperature, upper operating limit
70°C
Release class
CLASS 10
Temperature compensated overload protection
Voltage type for actuating
AC
Type of electrical connection of main circuit
Screw connection
Number of auxiliary contacts as normally closed contact
0
Rail mounting possible
With transformer
Number of indicator lights
4
Rated control supply voltage Us at AC 60HZ
110 .. 230V
Rated control supply voltage Us at AC 50HZ
110 .. 230V
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for TCP/IP
Supporting protocol for INTERBUS
Rated operation current Ie
2.4A
Degree of protection (IP)
IP20
With fuse
Supporting protocol for PROFIBUS
External reset possible
Supporting protocol for CAN
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Supporting protocol for SUCONET
Supporting protocol for DeviceNet
Supporting protocol for LON
Supporting protocol for PROFINET CBA
Suitable for emergency stop
Supporting protocol for PROFINET IO
Number of command positions
0
Supporting protocol for ASI
Supporting protocol for INTERBUS-Safety
Supporting protocol for Foundation Fieldbus
Supporting protocol for SERCOS
Supporting protocol for PROFIsafe
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for other bus systems
Supporting protocol for SafetyBUS p
Depth
113.4mm
Height
106.5mm
Width
22.6mm
From same serie