Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 60HZ
- - -V
Rated control supply voltage Us at AC 50HZ
- - -V
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Voltage type for actuating
DC
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
With short-circuit release
No
Type of motor starter
Reversing starter
Rated operation current Ie
2.4A
Overload release current setting
0.18 - 2.4A
Rated operation current at AC-3, 400 V
2.4A
Number of auxiliary contacts as normally closed contact
0
Rated power, 460 V, 60 Hz, 3-phase
0.75kW
Rated operation power at AC-3, 400 V
0.75kW
Number of auxiliary contacts as normally open contact
0
Rated control supply voltage Us at DC
24 - 24V
Ambient temperature, upper operating limit
70°C
Release class
CLASS 10
Temperature compensated overload protection
Yes
Rail mounting possible
Yes
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Type of electrical connection of main circuit
Screw connection
Number of command positions
0
Number of indicator lights
4
Supporting protocol for CAN
No
With transformer
No
External reset possible
Yes
Suitable for emergency stop
No
Supporting protocol for PROFIBUS
No
Degree of protection (IP)
IP20
Supporting protocol for TCP/IP
No
Supporting protocol for ASI
No
Supporting protocol for INTERBUS
No
With fuse
No
Supporting protocol for Modbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for SUCONET
No
Supporting protocol for PROFINET IO
No
Supporting protocol for LON
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for DeviceNet
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Height
106.5mm
Supporting protocol for other bus systems
No
Width
22.6mm
Depth
113.4mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LZ2H2X4BD

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 60HZ
- .. -V
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Voltage type for actuating
DC
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
With short-circuit release
Type of motor starter
Reversing starter
Rated operation current Ie
2.4A
Overload release current setting
0.18 .. 2.4A
Rated operation current at AC-3, 400 V
2.4A
Number of auxiliary contacts as normally closed contact
0
Rated power, 460 V, 60 Hz, 3-phase
0.75kW
Rated operation power at AC-3, 400 V
0.75kW
Number of auxiliary contacts as normally open contact
0
Rated control supply voltage Us at DC
24 .. 24V
Ambient temperature, upper operating limit
70°C
Release class
CLASS 10
Temperature compensated overload protection
Rail mounting possible
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Type of electrical connection of main circuit
Screw connection
Number of command positions
0
Number of indicator lights
4
Supporting protocol for CAN
With transformer
External reset possible
Suitable for emergency stop
Supporting protocol for PROFIBUS
Degree of protection (IP)
IP20
Supporting protocol for TCP/IP
Supporting protocol for ASI
Supporting protocol for INTERBUS
With fuse
Supporting protocol for Modbus
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Supporting protocol for LON
Supporting protocol for PROFINET CBA
Supporting protocol for SERCOS
Supporting protocol for DeviceNet
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Height
106.5mm
Supporting protocol for other bus systems
Width
22.6mm
Depth
113.4mm
From same serie