Aleta.hr
Main Product Image

LZ2H2X43FU

Code: 1758368

ManufacturerRAZNO
Catalog numberLZ2H2X43FU
Type
EAN code3606485421087

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at DC

- - -V

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 2, 400 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Rated control supply voltage Us at AC 50HZ

110 - 230V

Type of motor starter

Reversing starter

Voltage type for actuating

AC

Rated control supply voltage Us at AC 60HZ

110 - 230V

Rated power, 460 V, 60 Hz, 3-phase

0.75kW

Rated operation power at AC-3, 400 V

0.75kW

Rated operation current Ie

2.4A

Rated operation current at AC-3, 400 V

2.4A

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

0.18 - 2.4A

Temperature compensated overload protection

Yes

Release class

CLASS 10

Ambient temperature, upper operating limit

70°C

Type of electrical connection of main circuit

Spring clamp connection

Number of auxiliary contacts as normally open contact

0

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Rail mounting possible

Yes

With transformer

No

With short-circuit release

No

External reset possible

Yes

With fuse

No

Suitable for emergency stop

No

Number of indicator lights

4

Supporting protocol for TCP/IP

No

Supporting protocol for ASI

No

Supporting protocol for PROFIBUS

No

Degree of protection (IP)

IP20

Supporting protocol for Modbus

No

Supporting protocol for INTERBUS

No

Supporting protocol for DeviceNet

No

Supporting protocol for CAN

No

Supporting protocol for Data-Highway

No

Supporting protocol for LON

No

Supporting protocol for SUCONET

No

Number of command positions

0

Supporting protocol for PROFINET CBA

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for PROFINET IO

No

Supporting protocol for SERCOS

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for SafetyBUS p

No

Width

22.6mm

Supporting protocol for INTERBUS-Safety

No

Depth

113.4mm

Height

107.5mm

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for other bus systems

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

LZ2H2X43FU

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at DC

- .. -V

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 2, 400 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Rated control supply voltage Us at AC 50HZ

110 .. 230V

Type of motor starter

Reversing starter

Voltage type for actuating

AC

Rated control supply voltage Us at AC 60HZ

110 .. 230V

Rated power, 460 V, 60 Hz, 3-phase

0.75kW

Rated operation power at AC-3, 400 V

0.75kW

Rated operation current Ie

2.4A

Rated operation current at AC-3, 400 V

2.4A

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

0.18 .. 2.4A

Temperature compensated overload protection

Release class

CLASS 10

Ambient temperature, upper operating limit

70°C

Type of electrical connection of main circuit

Spring clamp connection

Number of auxiliary contacts as normally open contact

0

Type of electrical connection for auxiliary- and control current circuit

Spring clamp connection

Rail mounting possible

With transformer

With short-circuit release

External reset possible

With fuse

Suitable for emergency stop

Number of indicator lights

4

Supporting protocol for TCP/IP

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Degree of protection (IP)

IP20

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for LON

Supporting protocol for SUCONET

Number of command positions

0

Supporting protocol for PROFINET CBA

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET IO

Supporting protocol for SERCOS

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Width

22.6mm

Supporting protocol for INTERBUS-Safety

Depth

113.4mm

Height

107.5mm

Supporting protocol for Foundation Fieldbus

Supporting protocol for other bus systems

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.