Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- - -V
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Rated control supply voltage Us at AC 50HZ
110 - 230V
Type of motor starter
Reversing starter
Voltage type for actuating
AC
Rated control supply voltage Us at AC 60HZ
110 - 230V
Rated power, 460 V, 60 Hz, 3-phase
0.75kW
Rated operation power at AC-3, 400 V
0.75kW
Rated operation current Ie
2.4A
Rated operation current at AC-3, 400 V
2.4A
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
0.18 - 2.4A
Temperature compensated overload protection
Yes
Release class
CLASS 10
Ambient temperature, upper operating limit
70°C
Type of electrical connection of main circuit
Spring clamp connection
Number of auxiliary contacts as normally open contact
0
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
Rail mounting possible
Yes
With transformer
No
With short-circuit release
No
External reset possible
Yes
With fuse
No
Suitable for emergency stop
No
Number of indicator lights
4
Supporting protocol for TCP/IP
No
Supporting protocol for ASI
No
Supporting protocol for PROFIBUS
No
Degree of protection (IP)
IP20
Supporting protocol for Modbus
No
Supporting protocol for INTERBUS
No
Supporting protocol for DeviceNet
No
Supporting protocol for CAN
No
Supporting protocol for Data-Highway
No
Supporting protocol for LON
No
Supporting protocol for SUCONET
No
Number of command positions
0
Supporting protocol for PROFINET CBA
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for PROFINET IO
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Width
22.6mm
Supporting protocol for INTERBUS-Safety
No
Depth
113.4mm
Height
107.5mm
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for other bus systems
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LZ2H2X43FU

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- .. -V
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Rated control supply voltage Us at AC 50HZ
110 .. 230V
Type of motor starter
Reversing starter
Voltage type for actuating
AC
Rated control supply voltage Us at AC 60HZ
110 .. 230V
Rated power, 460 V, 60 Hz, 3-phase
0.75kW
Rated operation power at AC-3, 400 V
0.75kW
Rated operation current Ie
2.4A
Rated operation current at AC-3, 400 V
2.4A
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
0.18 .. 2.4A
Temperature compensated overload protection
Release class
CLASS 10
Ambient temperature, upper operating limit
70°C
Type of electrical connection of main circuit
Spring clamp connection
Number of auxiliary contacts as normally open contact
0
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
Rail mounting possible
With transformer
With short-circuit release
External reset possible
With fuse
Suitable for emergency stop
Number of indicator lights
4
Supporting protocol for TCP/IP
Supporting protocol for ASI
Supporting protocol for PROFIBUS
Degree of protection (IP)
IP20
Supporting protocol for Modbus
Supporting protocol for INTERBUS
Supporting protocol for DeviceNet
Supporting protocol for CAN
Supporting protocol for Data-Highway
Supporting protocol for LON
Supporting protocol for SUCONET
Number of command positions
0
Supporting protocol for PROFINET CBA
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFINET IO
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Width
22.6mm
Supporting protocol for INTERBUS-Safety
Depth
113.4mm
Height
107.5mm
Supporting protocol for Foundation Fieldbus
Supporting protocol for other bus systems
From same serie