Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 60HZ
- - -V
Rated control supply voltage Us at AC 50HZ
- - -V
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Type of motor starter
Direct online starter (DOL)
Voltage type for actuating
DC
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Rated operation power at AC-3, 400 V
0.75kW
Rated operation current Ie
2.4A
Number of auxiliary contacts as normally open contact
0
Ambient temperature, upper operating limit
70°C
Number of auxiliary contacts as normally closed contact
0
Temperature compensated overload protection
Yes
With transformer
No
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Number of indicator lights
3
Rail mounting possible
Yes
Overload release current setting
0.18 - 2.4A
With short-circuit release
No
Rated power, 460 V, 60 Hz, 3-phase
0.75kW
With fuse
No
Rated control supply voltage Us at DC
24 - 24V
Suitable for emergency stop
No
Degree of protection (IP)
IP20
Type of electrical connection of main circuit
Screw connection
Release class
CLASS 10
Number of command positions
0
External reset possible
Yes
Rated operation current at AC-3, 400 V
2.4A
Supporting protocol for TCP/IP
No
Supporting protocol for ASI
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for Data-Highway
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for Modbus
No
Supporting protocol for SafetyBUS p
No
Width
22.6mm
Supporting protocol for PROFIsafe
No
Supporting protocol for SERCOS
No
Supporting protocol for other bus systems
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for DeviceNet Safety
No
Depth
113.4mm
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Height
106.5mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LZ1H2X4BD

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 60HZ
- .. -V
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Type of motor starter
Direct online starter (DOL)
Voltage type for actuating
DC
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Rated operation power at AC-3, 400 V
0.75kW
Rated operation current Ie
2.4A
Number of auxiliary contacts as normally open contact
0
Ambient temperature, upper operating limit
70°C
Number of auxiliary contacts as normally closed contact
0
Temperature compensated overload protection
With transformer
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Number of indicator lights
3
Rail mounting possible
Overload release current setting
0.18 .. 2.4A
With short-circuit release
Rated power, 460 V, 60 Hz, 3-phase
0.75kW
With fuse
Rated control supply voltage Us at DC
24 .. 24V
Suitable for emergency stop
Degree of protection (IP)
IP20
Type of electrical connection of main circuit
Screw connection
Release class
CLASS 10
Number of command positions
0
External reset possible
Rated operation current at AC-3, 400 V
2.4A
Supporting protocol for TCP/IP
Supporting protocol for ASI
Supporting protocol for PROFIBUS
Supporting protocol for CAN
Supporting protocol for INTERBUS
Supporting protocol for Data-Highway
Supporting protocol for PROFINET CBA
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for Foundation Fieldbus
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Modbus
Supporting protocol for SafetyBUS p
Width
22.6mm
Supporting protocol for PROFIsafe
Supporting protocol for SERCOS
Supporting protocol for other bus systems
Supporting protocol for INTERBUS-Safety
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet Safety
Depth
113.4mm
Supporting protocol for LON
Supporting protocol for PROFINET IO
Height
106.5mm
From same serie