Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains voltage
220 - 220V
Mains frequency
50/60 Hz
Max. output frequency
16Hz
Max. output voltage
240V
Max. output at quadratic load at rated output voltage
0.2kW
Relative symmetric net voltage tolerance
10%
Application in industrial area permitted
Yes
Nominal output current I2N
1.5A
Number of phases output
3
Relative symmetric net frequency tolerance
5%
Number of analogue outputs
1
Number of phases input
1
Supporting protocol for PROFIBUS
No
Max. output at linear load at rated output voltage
0.2kW
Number of digital outputs
2
Supporting protocol for CAN
Yes
Number of digital inputs
6
Supporting protocol for Modbus
Yes
Supporting protocol for DeviceNet
No
Supporting protocol for Data-Highway
No
Supporting protocol for INTERBUS
No
Supporting protocol for KNX
No
Supporting protocol for SUCONET
No
Number of analogue inputs
3
Supporting protocol for EtherNet/IP
No
Supporting protocol for TCP/IP
No
Supporting protocol for SERCOS
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for PROFIsafe
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for PROFINET IO
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for LON
No
Supporting protocol for ASI
No
Application in domestic- and commercial area permitted
Yes
With control element
Yes
With PC connection
No
Integrated breaking resistance
Yes
4-quadrant operation possible
No
With optical interface
No
Type of converter
Direct converter
Degree of protection (IP)
IP20
Width
55mm
Height
150mm
Depth
146mm
Supporting protocol for BACnet
No
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces serial TTY
0
Supporting protocol for other bus systems
No
Number of HW-interfaces RS-232
0
Number of interfaces PROFINET
0
Number of HW-interfaces USB
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces RS-422
2
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LXM28AU02M3X
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains voltage
220 .. 220V
Mains frequency
50/60 Hz
Max. output frequency
16Hz
Max. output voltage
240V
Max. output at quadratic load at rated output voltage
0.2kW
Relative symmetric net voltage tolerance
10%
Application in industrial area permitted
Nominal output current I2N
1.5A
Number of phases output
3
Relative symmetric net frequency tolerance
5%
Number of analogue outputs
1
Number of phases input
1
Supporting protocol for PROFIBUS
Max. output at linear load at rated output voltage
0.2kW
Number of digital outputs
2
Supporting protocol for CAN
Number of digital inputs
6
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Supporting protocol for INTERBUS
Supporting protocol for KNX
Supporting protocol for SUCONET
Number of analogue inputs
3
Supporting protocol for EtherNet/IP
Supporting protocol for TCP/IP
Supporting protocol for SERCOS
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFINET IO
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET CBA
Supporting protocol for INTERBUS-Safety
Supporting protocol for DeviceNet Safety
Supporting protocol for LON
Supporting protocol for ASI
Application in domestic- and commercial area permitted
With control element
With PC connection
Integrated breaking resistance
4-quadrant operation possible
With optical interface
Type of converter
Direct converter
Degree of protection (IP)
IP20
Width
55mm
Height
150mm
Depth
146mm
Supporting protocol for BACnet
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces serial TTY
0
Supporting protocol for other bus systems
Number of HW-interfaces RS-232
0
Number of interfaces PROFINET
0
Number of HW-interfaces USB
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces RS-422
2
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
From same serie
We use cookies to enhance your experience.