![Main Product Image](https://assets.aleta.hr/415x415/c6b06912-d99c-412e-baea-eb93335f7f32.webp)
![Main Product Image](https://assets.aleta.hr/415x415/c6b06912-d99c-412e-baea-eb93335f7f32.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP40
Number of poles
3
Type of control element
Toggle
Number of auxiliary contacts as normally closed contact
0
Rated permanent current Iu
25A
Number of auxiliary contacts as normally open contact
0
Overload release current setting
17.5 - 25A
Type of electrical connection of main circuit
Screw connection
Number of auxiliary contacts as change-over contact
0
Motor drive optional
No
Motor drive integrated
No
Rated voltage
690 - 690V
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
Yes
Adjustment range undelayed short-circuit release
600 - 600A
With under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
16kA
Adjustment range short-term delayed short-circuit release
- - -A
Position of connection for main current circuit
Front side
Complete device with protection unit
Yes
Integrated earth fault protection
No
DIN rail (top hat rail) mounting optional
No
With switched-off indicator
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LV426151
![Main Product Image](https://assets.aleta.hr/300x300/f923fd2e-852b-441a-af7d-653f0c768d7b_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP40
Number of poles
3
Type of control element
Toggle
Number of auxiliary contacts as normally closed contact
0
Rated permanent current Iu
25A
Number of auxiliary contacts as normally open contact
0
Overload release current setting
17.5 .. 25A
Type of electrical connection of main circuit
Screw connection
Number of auxiliary contacts as change-over contact
0
Motor drive optional
Motor drive integrated
Rated voltage
690 .. 690V
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
Adjustment range undelayed short-circuit release
600 .. 600A
With under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
16kA
Adjustment range short-term delayed short-circuit release
- .. -A
Position of connection for main current circuit
Front side
Complete device with protection unit
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
With switched-off indicator
From same serie
We use cookies to enhance your experience.