Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
0 - 0V
Supply voltage AC 60 Hz
0 - 0V
Number of HW-interfaces RS-422
0
Max. number of time switches
0
Supply voltage DC
24 - 24V
Number of relay outputs
0
Number of HW-interfaces industrial Ethernet
3
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
0
Model
Modular
Number of HW-interfaces RS-232
0
Voltage type of supply voltage
AC/DC
Number of digital inputs
4096
Processing time (1K, binary operation)
0.01ms
Number of HW-interfaces other
64
Number of interfaces PROFINET
0
Number of analogue outputs
1024
Number of HW-interfaces USB
1
With optical interface
No
Supporting protocol for CAN
No
Number of digital outputs
4096
Number of HW-interfaces Wireless
0
Supporting protocol for TCP/IP
Yes
Supporting protocol for PROFIBUS
No
Number of analogue inputs
1024
Supporting protocol for Data-Highway
No
Supporting protocol for ASI
Yes
Supporting protocol for PROFINET CBA
No
Supporting protocol for LON
No
Supporting protocol for DeviceNet
No
Supporting protocol for INTERBUS
No
Supporting protocol for KNX
No
Supporting protocol for SUCONET
No
Supporting protocol for PROFINET IO
No
Supporting protocol for Modbus
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for DNP3
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for other bus systems
No
Supporting protocol for PROFIsafe
No
Supporting protocol for IEC 60870
No
Long-Term Evolution (LTE)
No
IO link master
No
System accessory
No
With display
Yes
Redundancy
No
Type of memory
NVRAM
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for INTERBUS-Safety
No
Memory size
18000kByte
Additional program memory possible
Yes
Rail mounting possible
No
Wall mounting/direct mounting
No
Suitable for safety functions
No
Rack-assembly possible
Yes
Front built-in possible
No
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
No
SIL according to IEC 61508
None
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
ATEX gas-ex-protection, Cat. 3G
Explosion safety category for dust
ATEX dust-ex-protection, Cat. 3D
Width
64.6mm
Height
134.6mm
Depth
130.3mm
Supporting protocol for IEC 61850 Ethernet
No
Radio standard Bluetooth
No
Radio standard Wi-Fi 802.11
No
Radio standard GPRS
No
Radio standard UMTS
No
Radio standard GSM
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
BMEP584020

Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- SCHNEIDER
Technical specifications
Supply voltage AC 50 Hz
0 .. 0V
Supply voltage AC 60 Hz
0 .. 0V
Number of HW-interfaces RS-422
0
Max. number of time switches
0
Supply voltage DC
24 .. 24V
Number of relay outputs
0
Number of HW-interfaces industrial Ethernet
3
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
0
Model
Modular
Number of HW-interfaces RS-232
0
Voltage type of supply voltage
AC/DC
Number of digital inputs
4096
Processing time (1K, binary operation)
0.01ms
Number of HW-interfaces other
64
Number of interfaces PROFINET
0
Number of analogue outputs
1024
Number of HW-interfaces USB
1
With optical interface
Supporting protocol for CAN
Number of digital outputs
4096
Number of HW-interfaces Wireless
0
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Number of analogue inputs
1024
Supporting protocol for Data-Highway
Supporting protocol for ASI
Supporting protocol for PROFINET CBA
Supporting protocol for LON
Supporting protocol for DeviceNet
Supporting protocol for INTERBUS
Supporting protocol for KNX
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Supporting protocol for Modbus
Supporting protocol for SafetyBUS p
Supporting protocol for DeviceNet Safety
Supporting protocol for DNP3
Supporting protocol for EtherNet/IP
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for other bus systems
Supporting protocol for PROFIsafe
Supporting protocol for IEC 60870
Long-Term Evolution (LTE)
IO link master
System accessory
With display
Redundancy
Type of memory
NVRAM
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for INTERBUS-Safety
Memory size
18000kByte
Additional program memory possible
Rail mounting possible
Wall mounting/direct mounting
Suitable for safety functions
Rack-assembly possible
Front built-in possible
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
SIL according to IEC 61508
None
Appendant operation agent (Ex ib)
Explosion safety category for gas
ATEX gas-ex-protection, Cat. 3G
Explosion safety category for dust
ATEX dust-ex-protection, Cat. 3D
Width
64.6mm
Height
134.6mm
Depth
130.3mm
Supporting protocol for IEC 61850 Ethernet
Radio standard Bluetooth
Radio standard Wi-Fi 802.11
Radio standard GPRS
Radio standard UMTS
Radio standard GSM
From same serie
We use cookies to enhance your experience.