![Main Product Image](https://assets.aleta.hr/415x415/9c0e7e1a-9e40-4125-9c9a-07b97c0dde85.webp)
![Main Product Image](https://assets.aleta.hr/415x415/9c0e7e1a-9e40-4125-9c9a-07b97c0dde85.webp)
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains voltage
380 - 440V
Number of phases input
3
Max. output frequency
500Hz
Max. output voltage
440V
Number of phases output
3
Relative symmetric net voltage tolerance
10%
Max. output at quadratic load at rated output voltage
315kW
With control element
Yes
Number of analogue inputs
3
Number of analogue outputs
2
Mains frequency
50/60 Hz
Number of digital inputs
8
Application in industrial area permitted
Yes
Number of digital outputs
1
Supporting protocol for PROFIBUS
Yes
Supporting protocol for TCP/IP
No
Max. output at linear load at rated output voltage
315kW
Application in domestic- and commercial area permitted
Yes
Nominal output current I2N
590A
Supporting protocol for CAN
Yes
Relative symmetric net frequency tolerance
5%
With optical interface
No
With PC connection
No
Integrated breaking resistance
No
4-quadrant operation possible
Yes
Type of converter
U converter
Degree of protection (IP)
IP54
Height
2350mm
Width
600mm
Depth
669mm
Supporting protocol for Modbus
No
Supporting protocol for ASI
No
Supporting protocol for INTERBUS
No
Supporting protocol for KNX
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for LON
No
Supporting protocol for SUCONET
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for BACnet
No
Supporting protocol for other bus systems
Yes
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-485
3
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV950C31N4F
![Main Product Image](https://assets.aleta.hr/300x300/4873bf05-8f69-488c-91b7-af965f3ac2d4_optimized.webp)
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains voltage
380 .. 440V
Number of phases input
3
Max. output frequency
500Hz
Max. output voltage
440V
Number of phases output
3
Relative symmetric net voltage tolerance
10%
Max. output at quadratic load at rated output voltage
315kW
With control element
Number of analogue inputs
3
Number of analogue outputs
2
Mains frequency
50/60 Hz
Number of digital inputs
8
Application in industrial area permitted
Number of digital outputs
1
Supporting protocol for PROFIBUS
Supporting protocol for TCP/IP
Max. output at linear load at rated output voltage
315kW
Application in domestic- and commercial area permitted
Nominal output current I2N
590A
Supporting protocol for CAN
Relative symmetric net frequency tolerance
5%
With optical interface
With PC connection
Integrated breaking resistance
4-quadrant operation possible
Type of converter
U converter
Degree of protection (IP)
IP54
Height
2350mm
Width
600mm
Depth
669mm
Supporting protocol for Modbus
Supporting protocol for ASI
Supporting protocol for INTERBUS
Supporting protocol for KNX
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Supporting protocol for LON
Supporting protocol for SUCONET
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIsafe
Supporting protocol for BACnet
Supporting protocol for other bus systems
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-485
3
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
0
From same serie
We use cookies to enhance your experience.