![Main Product Image](https://assets.aleta.hr/415x415/5ce643b2-e3ee-454a-bc83-f20c6871bf5c.webp)
![Main Product Image](https://assets.aleta.hr/415x415/5ce643b2-e3ee-454a-bc83-f20c6871bf5c.webp)
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Number of phases input
3
Number of phases output
3
Mains frequency
50/60 Hz
Relative symmetric net frequency tolerance
5%
Nominal output current I2N
106A
Max. output at linear load at rated output voltage
55kW
Number of analogue inputs
3
Mains voltage
380 - 480V
Max. output voltage
480V
Max. output frequency
500Hz
Relative symmetric net voltage tolerance
10%
Number of analogue outputs
2
Supporting protocol for PROFIBUS
Yes
Application in industrial area permitted
Yes
Number of digital inputs
8
Application in domestic- and commercial area permitted
Yes
Supporting protocol for CAN
Yes
Number of digital outputs
1
Max. output at quadratic load at rated output voltage
55kW
With control element
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for Data-Highway
No
Supporting protocol for ASI
No
Supporting protocol for LON
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for TCP/IP
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for Modbus
No
Supporting protocol for SUCONET
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for SERCOS
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for KNX
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SafetyBUS p
No
Number of HW-interfaces RS-232
0
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for other bus systems
Yes
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for BACnet
No
Number of interfaces PROFINET
0
With PC connection
No
With optical interface
Yes
Integrated breaking resistance
No
Degree of protection (IP)
IP21
4-quadrant operation possible
Yes
Type of converter
U converter
Height
922mm
Depth
325.5mm
Width
290mm
Supporting protocol for PROFIsafe
No
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
3
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV930D55N4
![Main Product Image](https://assets.aleta.hr/300x300/b82bd1a1-7512-4c42-91e9-68d0f8d56c37_optimized.webp)
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Number of phases input
3
Number of phases output
3
Mains frequency
50/60 Hz
Relative symmetric net frequency tolerance
5%
Nominal output current I2N
106A
Max. output at linear load at rated output voltage
55kW
Number of analogue inputs
3
Mains voltage
380 .. 480V
Max. output voltage
480V
Max. output frequency
500Hz
Relative symmetric net voltage tolerance
10%
Number of analogue outputs
2
Supporting protocol for PROFIBUS
Application in industrial area permitted
Number of digital inputs
8
Application in domestic- and commercial area permitted
Supporting protocol for CAN
Number of digital outputs
1
Max. output at quadratic load at rated output voltage
55kW
With control element
Supporting protocol for INTERBUS
Supporting protocol for Data-Highway
Supporting protocol for ASI
Supporting protocol for LON
Supporting protocol for DeviceNet
Supporting protocol for TCP/IP
Supporting protocol for PROFINET IO
Supporting protocol for Modbus
Supporting protocol for SUCONET
Supporting protocol for EtherNet/IP
Supporting protocol for SERCOS
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for KNX
Supporting protocol for PROFINET CBA
Supporting protocol for Foundation Fieldbus
Supporting protocol for SafetyBUS p
Number of HW-interfaces RS-232
0
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for other bus systems
Supporting protocol for INTERBUS-Safety
Supporting protocol for DeviceNet Safety
Supporting protocol for BACnet
Number of interfaces PROFINET
0
With PC connection
With optical interface
Integrated breaking resistance
Degree of protection (IP)
IP21
4-quadrant operation possible
Type of converter
U converter
Height
922mm
Depth
325.5mm
Width
290mm
Supporting protocol for PROFIsafe
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
3
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
From same serie