Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains voltage
380 - 480V
Mains frequency
50/60 Hz
Number of phases input
3
Number of phases output
3
Max. output frequency
500Hz
Max. output voltage
480V
Nominal output current I2N
616A
Max. output at quadratic load at rated output voltage
315kW
Max. output at linear load at rated output voltage
315kW
Relative symmetric net frequency tolerance
5%
Number of analogue outputs
2
Relative symmetric net voltage tolerance
10%
Number of analogue inputs
3
Number of digital inputs
8
With control element
Yes
Number of digital outputs
1
Supporting protocol for TCP/IP
No
Application in domestic- and commercial area permitted
Yes
Supporting protocol for PROFIBUS
Yes
Supporting protocol for ASI
No
Supporting protocol for CAN
Yes
Supporting protocol for INTERBUS
No
Application in industrial area permitted
Yes
Supporting protocol for KNX
No
Supporting protocol for Modbus
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for BACnet
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
Yes
With optical interface
Yes
With PC connection
No
Integrated breaking resistance
No
4-quadrant operation possible
Yes
Type of converter
U converter
Degree of protection (IP)
IP00
Height
1195mm
Width
598mm
Depth
380mm
Supporting protocol for other bus systems
Yes
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
3
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV930C31N4C
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains voltage
380 .. 480V
Mains frequency
50/60 Hz
Number of phases input
3
Number of phases output
3
Max. output frequency
500Hz
Max. output voltage
480V
Nominal output current I2N
616A
Max. output at quadratic load at rated output voltage
315kW
Max. output at linear load at rated output voltage
315kW
Relative symmetric net frequency tolerance
5%
Number of analogue outputs
2
Relative symmetric net voltage tolerance
10%
Number of analogue inputs
3
Number of digital inputs
8
With control element
Number of digital outputs
1
Supporting protocol for TCP/IP
Application in domestic- and commercial area permitted
Supporting protocol for PROFIBUS
Supporting protocol for ASI
Supporting protocol for CAN
Supporting protocol for INTERBUS
Application in industrial area permitted
Supporting protocol for KNX
Supporting protocol for Modbus
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET CBA
Supporting protocol for DeviceNet Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for EtherNet/IP
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for BACnet
Supporting protocol for SafetyBUS p
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
With optical interface
With PC connection
Integrated breaking resistance
4-quadrant operation possible
Type of converter
U converter
Degree of protection (IP)
IP00
Height
1195mm
Width
598mm
Depth
380mm
Supporting protocol for other bus systems
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
3
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
0