Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Number of phases input
3
Number of phases output
3
Mains voltage
380 - 440V
Number of analogue outputs
2
Max. output frequency
500Hz
Mains frequency
50/60 Hz
Max. output at quadratic load at rated output voltage
315kW
Relative symmetric net frequency tolerance
5%
Relative symmetric net voltage tolerance
10%
Nominal output current I2N
590A
Max. output voltage
440V
Max. output at linear load at rated output voltage
315kW
Number of digital outputs
0
Supporting protocol for TCP/IP
Yes
Application in domestic- and commercial area permitted
Yes
Supporting protocol for ASI
No
Number of analogue inputs
3
Supporting protocol for INTERBUS
No
Application in industrial area permitted
Yes
Number of digital inputs
6
Supporting protocol for KNX
No
With control element
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for CAN
No
Supporting protocol for Modbus
Yes
Supporting protocol for SUCONET
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for PROFINET CBA
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for DeviceNet Safety
No
Number of HW-interfaces industrial Ethernet
1
Supporting protocol for PROFIBUS
Yes
Supporting protocol for BACnet
No
Supporting protocol for SERCOS
No
Number of interfaces PROFINET
0
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for DeviceNet
Yes
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for SafetyBUS p
No
With optical interface
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for LON
No
With PC connection
No
Integrated breaking resistance
No
Type of converter
U converter
Degree of protection (IP)
IP54
Height
2350mm
Depth
669mm
Width
600mm
4-quadrant operation possible
Yes
Number of HW-interfaces USB
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV650C31N4F
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Number of phases input
3
Number of phases output
3
Mains voltage
380 .. 440V
Number of analogue outputs
2
Max. output frequency
500Hz
Mains frequency
50/60 Hz
Max. output at quadratic load at rated output voltage
315kW
Relative symmetric net frequency tolerance
5%
Relative symmetric net voltage tolerance
10%
Nominal output current I2N
590A
Max. output voltage
440V
Max. output at linear load at rated output voltage
315kW
Number of digital outputs
0
Supporting protocol for TCP/IP
Application in domestic- and commercial area permitted
Supporting protocol for ASI
Number of analogue inputs
3
Supporting protocol for INTERBUS
Application in industrial area permitted
Number of digital inputs
6
Supporting protocol for KNX
With control element
Supporting protocol for Data-Highway
Supporting protocol for CAN
Supporting protocol for Modbus
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet Safety
Number of HW-interfaces industrial Ethernet
1
Supporting protocol for PROFIBUS
Supporting protocol for BACnet
Supporting protocol for SERCOS
Number of interfaces PROFINET
0
Supporting protocol for INTERBUS-Safety
Supporting protocol for DeviceNet
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Supporting protocol for EtherNet/IP
Supporting protocol for SafetyBUS p
With optical interface
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for LON
With PC connection
Integrated breaking resistance
Type of converter
U converter
Degree of protection (IP)
IP54
Height
2350mm
Depth
669mm
Width
600mm
4-quadrant operation possible
Number of HW-interfaces USB
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
From same serie
We use cookies to enhance your experience.