Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains voltage
380 - 500V
Mains frequency
50/60 Hz
Number of phases output
3
Max. output at linear load at rated output voltage
3kW
Number of phases input
3
Relative symmetric net frequency tolerance
5%
Number of analogue outputs
1
Max. output at quadratic load at rated output voltage
3kW
Nominal output current I2N
7.1A
Max. output frequency
599Hz
Relative symmetric net voltage tolerance
10%
Max. output voltage
500V
Application in industrial area permitted
Yes
Number of analogue inputs
3
Number of digital inputs
6
Number of digital outputs
1
Application in domestic- and commercial area permitted
No
With control element
Yes
Supporting protocol for PROFIBUS
Yes
Supporting protocol for TCP/IP
No
Supporting protocol for Modbus
Yes
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for SUCONET
No
Supporting protocol for CAN
Yes
Supporting protocol for LON
No
Supporting protocol for Data-Highway
No
Supporting protocol for INTERBUS
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for PROFINET IO
Yes
With optical interface
No
With PC connection
Yes
Supporting protocol for DeviceNet Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for SERCOS
No
Number of interfaces PROFINET
0
Integrated breaking resistance
No
Number of HW-interfaces parallel
0
Number of HW-interfaces serial TTY
0
Supporting protocol for BACnet
No
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces RS-422
0
4-quadrant operation possible
Yes
Number of HW-interfaces USB
0
Supporting protocol for Foundation Fieldbus
No
Type of converter
U converter
Degree of protection (IP)
IP20
Degree of protection (NEMA)
1
Height
184mm
Width
140mm
Depth
158mm
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for PROFINET CBA
No
Supporting protocol for other bus systems
Yes
Number of HW-interfaces other
1
Number of HW-interfaces RS-232
0
Supporting protocol for SafetyBUS p
No
Number of HW-interfaces RS-485
1
Supporting protocol for PROFIsafe
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV320U30N4C
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains voltage
380 .. 500V
Mains frequency
50/60 Hz
Number of phases output
3
Max. output at linear load at rated output voltage
3kW
Number of phases input
3
Relative symmetric net frequency tolerance
5%
Number of analogue outputs
1
Max. output at quadratic load at rated output voltage
3kW
Nominal output current I2N
7.1A
Max. output frequency
599Hz
Relative symmetric net voltage tolerance
10%
Max. output voltage
500V
Application in industrial area permitted
Number of analogue inputs
3
Number of digital inputs
6
Number of digital outputs
1
Application in domestic- and commercial area permitted
With control element
Supporting protocol for PROFIBUS
Supporting protocol for TCP/IP
Supporting protocol for Modbus
Supporting protocol for ASI
Supporting protocol for KNX
Supporting protocol for SUCONET
Supporting protocol for CAN
Supporting protocol for LON
Supporting protocol for Data-Highway
Supporting protocol for INTERBUS
Supporting protocol for DeviceNet
Supporting protocol for PROFINET IO
With optical interface
With PC connection
Supporting protocol for DeviceNet Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for SERCOS
Number of interfaces PROFINET
0
Integrated breaking resistance
Number of HW-interfaces parallel
0
Number of HW-interfaces serial TTY
0
Supporting protocol for BACnet
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces RS-422
0
4-quadrant operation possible
Number of HW-interfaces USB
0
Supporting protocol for Foundation Fieldbus
Type of converter
U converter
Degree of protection (IP)
IP20
Degree of protection (NEMA)
1
Height
184mm
Width
140mm
Depth
158mm
Supporting protocol for INTERBUS-Safety
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET CBA
Supporting protocol for other bus systems
Number of HW-interfaces other
1
Number of HW-interfaces RS-232
0
Supporting protocol for SafetyBUS p
Number of HW-interfaces RS-485
1
Supporting protocol for PROFIsafe
From same serie
We use cookies to enhance your experience.