Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- ABB
Technical specifications
Voltage protection level L-N
-kV
Voltage protection level N-PE
-kV
Max. PV-voltage
-V
Follow current extinguishing capability
-kA
Voltage protection level (DC+ - DC-)
-kV
Specific energy (W/R)
-kJ/Ohm
Voltage protection level (DC+/DC- - PE)
-kV
System configuration DC
No
System configuration TT
Yes
System configuration IT
No
System configuration TN-S
Yes
System configuration TN-C-S
No
Max. continuous voltage AC
275V
System configuration other
No
System configuration TN-C
Yes
Number of poles
3
Voltage protection level L-PE
1.4kV
Max. conductor cross section solid (solid, stranded)
35mm²
System configuration TN
Yes
Mounting method
DIN rail (top hat rail) 35 mm
Max. conductor cross section flexible (fine-strand)
25mm²
Signalling at the device
Optic
Exhausting
No
Max. continuous voltage DC
350V
Voltage protection level
1.3kV
Test class
Type 1 + 2
Remote signalling
Yes
Integrated backup fuse
No
Construction size
3 modular spacing
Energy-coordinated protection effect with regard to the terminal equipment
No
Degree of protection (IP)
IP20
Nominal voltage DC
350V
Lightning impulse current (10/350 µs)
12.5kA
Nominal voltage AC
230V
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
2CTB815710R0600 | OVR T1-T2 3L 12.5-275s P TS QS

Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- ABB
Technical specifications
Voltage protection level L-N
-kV
Voltage protection level N-PE
-kV
Max. PV-voltage
-V
Follow current extinguishing capability
-kA
Voltage protection level (DC+ - DC-)
-kV
Specific energy (W/R)
-kJ/Ohm
Voltage protection level (DC+/DC- - PE)
-kV
System configuration DC
System configuration TT
System configuration IT
System configuration TN-S
System configuration TN-C-S
Max. continuous voltage AC
275V
System configuration other
System configuration TN-C
Number of poles
3
Voltage protection level L-PE
1.4kV
Max. conductor cross section solid (solid, stranded)
35mm²
System configuration TN
Mounting method
DIN rail (top hat rail) 35 mm
Max. conductor cross section flexible (fine-strand)
25mm²
Signalling at the device
Optic
Exhausting
Max. continuous voltage DC
350V
Voltage protection level
1.3kV
Test class
Type 1 + 2
Remote signalling
Integrated backup fuse
Construction size
3 modular spacing
Energy-coordinated protection effect with regard to the terminal equipment
Degree of protection (IP)
IP20
Nominal voltage DC
350V
Lightning impulse current (10/350 µs)
12.5kA
Nominal voltage AC
230V