Technical specifications
Version as main switch
Yes
Version as safety switch
No
Version as reversing switch
No
Version as maintenance-/service switch
Yes
Number of switches
1
Max. rated operation voltage Ue AC
690V
Rated permanent current Iu
63A
Rated permanent current at AC-21, 400 V
63A
Rated permanent current at AC-23, 400 V
63A
Version as emergency stop installation
Yes
Rated short-time withstand current lcw
1.26kA
Conditioned rated short-circuit current Iq
100kA
Rated operating voltage
690 - 690V
Motor drive integrated
No
Voltage release optional
No
Number of auxiliary contacts as normally closed contact
0
Rated operation power at AC-23, 400 V
30kW
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Switching power at 400 V
30kW
Device construction
Built-in device fixed built-in technique
Motor drive optional
No
Suitable for front mounting 4-hole
No
Suitable for front mounting centre
No
Number of auxiliary contacts as change-over contact
0
Suitable for distribution board installation
No
Type of control element
Door coupling rotary drive
Suitable for intermediate mounting
No
Colour control element
Red
Suitable for floor mounting
Yes
Interlockable
Yes
Rated operation power at AC-3, 400 V
30kW
Width
87mm
Type of electrical connection of main circuit
Screw connection
Height
102mm
With pre-assembled cabling
No
Degree of protection (NEMA)
12
Depth
147mm
Degree of protection (IP), front side
IP65
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
P3-63/V/SVB

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as main switch
Version as safety switch
Version as reversing switch
Version as maintenance-/service switch
Number of switches
1
Max. rated operation voltage Ue AC
690V
Rated permanent current Iu
63A
Rated permanent current at AC-21, 400 V
63A
Rated permanent current at AC-23, 400 V
63A
Version as emergency stop installation
Rated short-time withstand current lcw
1.26kA
Conditioned rated short-circuit current Iq
100kA
Rated operating voltage
690 .. 690V
Motor drive integrated
Voltage release optional
Number of auxiliary contacts as normally closed contact
0
Rated operation power at AC-23, 400 V
30kW
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Switching power at 400 V
30kW
Device construction
Built-in device fixed built-in technique
Motor drive optional
Suitable for front mounting 4-hole
Suitable for front mounting centre
Number of auxiliary contacts as change-over contact
0
Suitable for distribution board installation
Type of control element
Door coupling rotary drive
Suitable for intermediate mounting
Colour control element
Red
Suitable for floor mounting
Interlockable
Rated operation power at AC-3, 400 V
30kW
Width
87mm
Type of electrical connection of main circuit
Screw connection
Height
102mm
With pre-assembled cabling
Degree of protection (NEMA)
12
Depth
147mm
Degree of protection (IP), front side
IP65
From same serie