Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Rated permanent current Iu
400A
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact
0
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range undelayed short-circuit release
800 - 4400A
Number of auxiliary contacts as change-over contact
0
Overload release current setting
400 - 400A
Adjustment range short-term delayed short-circuit release
800 - 4000A
Type of electrical connection of main circuit
Screw connection
Integrated earth fault protection
No
With integrated under voltage release
No
Rated voltage
690 - 690V
Number of poles
3
Position of connection for main current circuit
Front side
Type of control element
Rocker lever
With switched-off indicator
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Motor drive optional
Yes
Complete device with protection unit
Yes
Degree of protection (IP)
IP20
Motor drive integrated
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
NZMN3-VEF400-NA

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Rated permanent current Iu
400A
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact
0
Suitable for DIN rail (top hat rail) mounting
Adjustment range undelayed short-circuit release
800 .. 4400A
Number of auxiliary contacts as change-over contact
0
Overload release current setting
400 .. 400A
Adjustment range short-term delayed short-circuit release
800 .. 4000A
Type of electrical connection of main circuit
Screw connection
Integrated earth fault protection
With integrated under voltage release
Rated voltage
690 .. 690V
Number of poles
3
Position of connection for main current circuit
Front side
Type of control element
Rocker lever
With switched-off indicator
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Motor drive optional
Complete device with protection unit
Degree of protection (IP)
IP20
Motor drive integrated
From same serie
Related products