Aleta.hr
Main Product Image

MSC-DM-12-M12(230V50HZ)/MSFA

Code: 1746809

ManufacturerRAZNO
Catalog number191124
Type
EAN code4015081916221

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for DeviceNet Safety

No

With short-circuit release

Yes

Rated control supply voltage Us at AC 50HZ

230 - 230V

Rated control supply voltage Us at DC

0 - 0V

Rated control supply voltage Us at AC 60HZ

0 - 0V

Voltage type for actuating

AC

Rated operation power at AC-3, 230 V, 3-phase

3kW

Rated operation power at AC-3, 400 V

5.5kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current Ie

11.3A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Overload release current setting

8 - 12A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated operation current at AC-3, 400 V

12A

Rated conditional short-circuit current, type 2, 230 V

0A

Rated conditional short-circuit current, type 2, 400 V

100A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Power consumption

1.4W

Number of auxiliary contacts as normally open contact

1

Number of auxiliary contacts as normally closed contact

0

Ambient temperature, upper operating limit

55°C

Release class

CLASS 10 A

Temperature compensated overload protection

Yes

With transformer

No

Type of electrical connection of main circuit

Screw connection

Number of command positions

0

Rail mounting possible

No

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Suitable for emergency stop

No

Coordination class according to IEC 60947-4-3

Class 1

External reset possible

No

Number of indicator lights

0

With fuse

No

Degree of protection (IP)

IP20

Degree of protection (NEMA)

Other

Supporting protocol for TCP/IP

No

Supporting protocol for PROFIBUS

No

Supporting protocol for CAN

No

Supporting protocol for ASI

No

Supporting protocol for INTERBUS

No

Supporting protocol for Modbus

No

Supporting protocol for Data-Highway

No

Supporting protocol for DeviceNet

No

Supporting protocol for LON

No

Supporting protocol for SUCONET

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for PROFINET IO

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for SERCOS

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for other bus systems

No

Width

45mm

Height

180mm

Depth

115mm

Supporting protocol for EtherNet/IP

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-DM-12-M12(230V50HZ)/MSFA

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

With short-circuit release

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rated control supply voltage Us at DC

0 .. 0V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Voltage type for actuating

AC

Rated operation power at AC-3, 230 V, 3-phase

3kW

Rated operation power at AC-3, 400 V

5.5kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current Ie

11.3A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Overload release current setting

8 .. 12A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated operation current at AC-3, 400 V

12A

Rated conditional short-circuit current, type 2, 230 V

0A

Rated conditional short-circuit current, type 2, 400 V

100A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Power consumption

1.4W

Number of auxiliary contacts as normally open contact

1

Number of auxiliary contacts as normally closed contact

0

Ambient temperature, upper operating limit

55°C

Release class

CLASS 10 A

Temperature compensated overload protection

With transformer

Type of electrical connection of main circuit

Screw connection

Number of command positions

0

Rail mounting possible

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Suitable for emergency stop

Coordination class according to IEC 60947-4-3

Class 1

External reset possible

Number of indicator lights

0

With fuse

Degree of protection (IP)

IP20

Degree of protection (NEMA)

Other

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for ASI

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for LON

Supporting protocol for SUCONET

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Width

45mm

Height

180mm

Depth

115mm

Supporting protocol for EtherNet/IP

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.