MSC-DM-10-M9(230V50HZ)/MSFA
Code: 1746807
Sign in or create an account for lower prices and other benefits
Code: 1746807
Sign in or create an account for lower prices and other benefits
Technical specifications
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at DC
0 - 0V
Overload release current setting
6.3 - 10A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated control supply voltage Us at AC 50HZ
230 - 230V
With short-circuit release
Yes
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation power at AC-3, 230 V, 3-phase
2.2kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated operation current Ie
8.5A
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated operation power at AC-3, 400 V
4kW
Rated operation current at AC-3, 400 V
9A
Rated conditional short-circuit current, type 2, 230 V
0A
Voltage type for actuating
AC
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Height
180mm
Width
45mm
Depth
115mm
Rail mounting possible
No
Temperature compensated overload protection
Yes
Type of electrical connection for auxiliary- and control current circuit
Screw connection
With transformer
No
Release class
CLASS 10 A
Number of command positions
0
Degree of protection (NEMA)
Other
Ambient temperature, upper operating limit
55°C
Rated conditional short-circuit current, type 2, 400 V
100A
Power consumption
1.4W
Supporting protocol for TCP/IP
No
Coordination class according to IEC 60947-4-3
Class 1
Degree of protection (IP)
IP20
Number of auxiliary contacts as normally open contact
1
Number of auxiliary contacts as normally closed contact
0
Number of indicator lights
0
Supporting protocol for INTERBUS
No
External reset possible
No
Supporting protocol for ASI
No
Supporting protocol for CAN
No
Type of electrical connection of main circuit
Screw connection
With fuse
No
Supporting protocol for Modbus
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for DeviceNet
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for SERCOS
No
Supporting protocol for PROFIBUS
No
Supporting protocol for Data-Highway
No
Suitable for emergency stop
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for SUCONET
No
Zagreb:
0 pcs
Zadar:
0 pcs
MSC-DM-10-M9(230V50HZ)/MSFA
Total stock:
0 PCS
Direct online starter (DOL)
0 .. 0V
6.3 .. 10A
0kW
230 .. 230V
0A
2.2kW
0kW
0A
8.5A
0 .. 0V
4kW
9A
0A
AC
180mm
45mm
115mm
Screw connection
CLASS 10 A
0
Other
55°C
100A
1.4W
Class 1
IP20
1
0
0
Screw connection
We use cookies to enhance your experience.